Specifications
Mains Supply 3 x 200 - 240V AC
FC 301/FC 302
1)
High/ Normal Load
Typical Shaft Output [kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, 66
Output current
Continuous
(3 x 200-240V) [A]
Intermittent
(60 sec overload)
(3 x 200-240V) [A]
Continuous
kVA (208V AC) [kVA]
Max. input current
Continuous
(3 x 200-240V) [A]
Intermittent
(60 sec overload)
(3 x 200-240V) [A]
Additional specifications
Max. cable size, IP20 [mm
2)
(AWG)]
Max. cable size, IP21/55/66
2
2)
[mm
(AWG)]
Max cable size with mains
2
2)
disconnect [mm
(AWG)]
Estimated power loss
4)
at rated max. load [W]
Weight,
enclosure IP21, IP 55, 66 [kg]
4)
Efficiency
Mains Supply 3 x 380 - 500V AC (FC 302), 3 x 380 - 480V AC (FC 301)
FC 301/FC 302
Typical Shaft Output [kW]
Enclosure IP20/IP21
Enclosure IP20 (FC 301 only)
Enclosure IP55, 66
Output current
High overload 160% for 1 min.
Shaft output [kW]
Continuous
(3 x 380-440V) [A]
Intermittent
(3 x 380-440V) [A]
Continuous
(3 x 441-500V) [A]
Intermittent
(3 x 441-500V) [A]
Continuous kVA
(400V AC) [kVA]
Continuous kVA
(460V AC) [kVA]
Max. input current
Continuous
(3 x 380-440V) [A]
Intermittent
(3 x 380-440V) [A]
Continuous
(3 x 441-500V) [A]
Intermittent
(3 x 441-500V) [A]
Additional specifications
Max. cable size
(mains, motor, brake)
2)
2
[AWG]
[mm
]
Estimated power loss
4)
at rated max. load [W]
Weight,
enclosure IP20
Enclosure IP55, 66
4)
Efficiency
0.37 - 7.5 kW only available as 160% high overload.
®
VLT
AutomationDrive Operating
Instructions
P15K
P18K
HO
NO
HO
15
18.5
18.5
B4
C1
C1
59.4
74.8
74.8
89.1
82.3
112
21.4
26.9
26.9
54
68
68
81
74.8
102
2
35 (2)
90 (3/0)
90 (3/0)
90 (3/0)
35 (2)
624
737
740
45
0.96
PK 37
PK 55
PK75
0.37
0.55
0.75
A2
A2
A2
A1
A1
A1
A4/A5
A4/A5
A4/A5
0.37
0.55
0.75
1.3
1.8
2.4
2.1
2.9
3.8
1.2
1.6
2.1
1.9
2.6
3.4
0.9
1.3
1.7
0.9
1.3
1.7
1.2
1.6
2.2
1.9
2.6
3.5
1.0
1.4
1.9
1.6
2.2
3.0
35
42
46
4.7
4.7
4.8
13.5
13.5
13.5
0.93
0.95
0.96
®
MG.33.AJ.02 - VLT
is a registered Danfoss trademark
P22K
NO
HO
NO
22
22
30
C3
C3
C1
C1
C1
C1
88
88
115
96.8
132
127
31.7
31.7
41.4
80
80
104
88
120
114
90 (3/0)
90 (3/0)
845
874
1140
45
45
0.97
0.97
P1K1
P1K5
P2K2
1.1
1.5
2.2
A2
A2
A2
A1
A1
A4/A5
A4/A5
A4/A5
1.1
1.5
2.2
3
4.1
5.6
4.8
6.6
9.0
2.7
3.4
4.8
4.3
5.4
7.7
2.1
2.8
3.9
2.4
2.7
3.8
2.7
3.7
5.0
4.3
5.9
8.0
2.7
3.1
4.3
4.3
5.0
6.9
24 - 10 AWG
2
0.2 - 4mm
58
62
88
4.8
4.9
4.9
13.5
13.5
13.5
0.96
0.97
0.97
P30K
P37K
HO
NO
HO
NO
30
37
37
45
C4
C4
C1
C1
C2
C2
115
143
143
170
173
157
215
187
41.4
51.5
51.5
61.2
104
130
130
154
156
143
195
169
120 (4/0)
120 (4/0)
120 (4/0)
120 (4/0)
70 (3/0)
150 (MCM 300)
1143
1353
1400
1636
65
65
0.97
0.97
P3K0
P4K0
P5K5
P7K5
3
4
5.5
7.5
A2
A2
A3
A3
A4/A5
A4/A5
A5
A5
3
4
5.5
7.5
7.2
10
13
16
11.5
16
20.8
25.6
6.3
8.2
11
14.5
10.1
13.1
17.6
23.2
5.0
6.9
9.0
11.0
5.0
6.5
8.8
11.6
6.5
9.0
11.7
14.4
10.4
14.4
18.7
23.0
5.7
7.4
9.9
13.0
9.1
11.8
15.8
20.8
24 - 10 AWG
2
0.2 - 4mm
116
124
187
255
4.9
4.9
6.6
6.6
13.5
13.5
14.2
14.2
0.97
0.97
0.97
0.97
10
10
63

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents