Festo CPX-E-EP Manual page 30

System cpx-e, bus module, protocol, ethernet/ip, modbus tcp, industrial ethernet 2-port
Table of Contents

Advertisement

3
Parameterisation
Diagnostics Trace Status Object
Object class: 135
d
Instances: 1
Attribute no.
Access
1
Get
2
Get
3
Get/Set
4
Get/Set
5
Get/Set
6
Get/Set
7
Get/Set
8
Get/Set
9
Get/Set
10
Get/Set
11
Get/Set
12
Get/Set
13
Get/Set
Tab. 3.20
30
Description
Number of trace entries in the diagnostic
memory
Status of diagnostic memory (bit 0, 1)
0 = Registering active
1 = Registering inactive
Clear_trace1, access via EDS
Clear_trace2, access via Explicit Messaging;
Confirms activity carried out by resetting (0)
the attribute value
Entries saved retentively with Power On (bit 0)
0 = Active (presetting)
1 = Inactive
Run/stop filter 1 (bit 1)
0 = Save the first 40 entries, stop after 40 entries
1 = Save the last 40 entries, overwrite existing
entries (presetting)
Run/stop filter 2 (bit 0 ... 2)
0 = Run/stop filter 2 inactive (presetting)
1 = Record up to the defined error number (FN)
2 = Record up to the defined FN + module
number (MN)
3 = Record up to the defined FN + MN + channel
number (KN)
4 = Record from the defined FN
5 = Record from the defined FN + MN
6 = Record from the defined FN + MN + KN
7 = Reserved
Error end filter (bit 3)
0 =Filter inactive, record running errors
(end of error) (presetting)
1 = Filter active, do not record running errors
(end of error)
Error number filter (bit 4, 5)
0 = Filter inactive (presetting)
1 = Record only defined error numbers
2 = Do not record defined error numbers
3 = Reserved
Module/channel filter (bit 6, 7)
With this diagnostic memory filter, the recording
of errors of other modules or channels can be
suppressed so that errors in a particular module
or channel can be analysed.
0 = Filter inactive (presetting)
1 = Record only the error numbers of a module
2 = Record only the error numbers of a channel
3 = Reserved
Module number for the diagnostic memory filter
Channel number for the diagnostic memory filter BYTE
Error number for the diagnostic memory filter
Type
Function number
BYTE
3482 (bit 0 ... 7)
BYTE
3483 (bit 0, 1)
BYTE
BYTE
BYTE
3480 (bit 0)
BYTE
3480 (bit 1)
BYTE
3484 (bit 0 ... 2)
BYTE
3484 (bit 3)
BYTE
3484 (bit 4, 5)
BYTE
3484 (bit 6, 7)
BYTE
3485 (bit 0 ... 7)
3486 (bit 0 ... 7)
BYTE
3487 (bit 0 ... 7)
Festo – CPX-E-EP-EN – 2017-07 – English