3
Parameterisation
Global System Object
Object class: 132
d
Instances: 1
Attribute no.
Access
1
Get
2
Get
3
Get
4
Get
5
Get
9
Get/Set
1) Indicates whether the current expansion of the system CPX-E corresponds to the saved expansion.
2) SCS = Short circuit/overload in sensor supply
3) SCO = Short circuit/overload at the outputs
4) SCV = Short circuit at valves
5) Presetting
Festo – CPX-E-EP-EN – 2017-07 – English
Description
Operating mode (bit 0, 1)
0 = Without control
1 = With control
1)
CPX-E expansion
(bit 4)
0 = Uniform expansion
1 = Nonuniform expansion
Force mode (bit 6)
0 = Force blocked
1 = Force enabled
Fail safe mode (bit 0, 1)
0 = Fail safe mode inactive
1 = Fail safe mode active
System Idle mode (bit 2, 3)
0 = Idle mode inactive
1 = Idle mode active
Monitoring of system CPX-E
2)
Bit 0
0 = SCS
monitoring inactive
2)
1 = SCS
monitoring active
3)
Bit 1
0 = SCO
monitoring inactive
3)
1 = SCO
monitoring active
Bit 2
0 = U
monitoring inactive
OUT
1 = U
monitoring active
OUT
Bit 3
0 = U
monitoring inactive
VAL
1 = U
monitoring active
VAL
4)
Bit 4
0 = SCV
monitoring inactive
4)
1 = SCV
monitoring active
Bit 5 ... 7
Reserved
Number of input bytes (Rx size)
Number of output bytes (Tx size)
Monitoring (presetting: active)
2)
Bit 0
0 = SCS
monitoring inactive
2)
1 = SCS
monitoring active
3)
Bit 1
0 = SCO
monitoring inactive
3)
1 = SCO
monitoring active
Bit 2
0 = U
monitoring inactive
OUT
1 = U
monitoring active
OUT
Bit 3
0 = U
monitoring inactive
VAL
1 = U
monitoring active
VAL
4)
Bit 4
0 = SCV
monitoring inactive
4)
1 = SCV
monitoring active
Bit 5 ... 7
Reserved
Type
Function number
USINT
0 (bit 0, 1)
0 (bit 4)
0 (bit 6)
USINT
1 (bit 0, 1)
1 (bit 2, 3)
USINT
2 (bit 0 ... 7)
UINT
USINT
USINT
4401 (bit 0 ... 7)
27

Advertisement

Table of Contents
loading

Table of Contents