Festo CPX-E-EP Manual page 20

System cpx-e, bus module, protocol, ethernet/ip, modbus tcp, industrial ethernet 2-port
Table of Contents

Advertisement

3
Parameterisation
TCP/IP Interface Object
Object class: 245
d
Instances: 1
Configuration of TCP/IP network interface.
Attribute no.
Access
1
Get
2
Get (NV)
3
Set (NV)
4
Get (NV)
5
Set (NV)
6
Set (NV)
8
Set (NV)
9
Get (NV)
10
Set (NV)
11
Set (NV)
12
Set (NV)
13
Set (NV)
Tab. 3.5
20
Description
Interface status
Configuration capability
Bit 0
BOOTP client (false)
Bit 1
DNS client (true)
Bit 2
DHCP client (true)
Bit 3
DHCP-DNS update (false)
Bit 4
Configuration settable (true)
Bit 5
Hardware configurable (true)
Bit 6
Interface configuration – change requires reset
(false)
Bit 7
AcdCapable (true)
Configuration control
Physical link object
Path size; path
Interface configuration:
IP address
Netmask
Gateway address
Name server
Name server 2
Domain name
HostName (max. 64 chars)
TTL value – 1 ... 255 (default = 1)
Mcast config (IP multicast address configuration):
Alloc control
Reserved
Num Mcast
Mcast start addr
SelectAcd
0 = Enable ACD
1 = Disable ACD
LastConflictDetected:
ACDactivity
RemoteMAC
ArpPDU
QuickConnect
0 = Disable
1 = Enable
Encapsulation inactivity timeout
0 = Disable
1 ... 3600 = Timeout in seconds (default = 120)
Type
DWORD
DWORD
DWORD
STRUCT of UINT +
Padded EPATH
STRUCT of
UDINT
UDINT
UDINT
UDINT
UDINT
STRING
STRING
USINT
STRUCT of
USINT
USINT
UINT
UDINT
BOOL
STRUCT of
USINT
ARRAY of
USINT [6]
ARRAY of
USINT [28]
BOOL
UINT
Festo – CPX-E-EP-EN – 2017-07 – English

Advertisement

Table of Contents
loading

Table of Contents