reMOve eSCuTCHeON
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the control panel (see page 4-1).
2.
Remove the two remaining T-20 security
screws from the front of the control panel.
T-20 screws
3.
To avoid damage, pull the escutcheon away
from the control panel and set it on a towel
or piece of cardboard.
reMOve DiSPLaY LeNS
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the control panel (see page 4-1).
2.
Remove the escutcheon (see page 4-7).
3.
Pull the escutcheon away from the front of
the control panel and the lens will be pulled
from the back of the escutcheon.
4-7
Display lens
Need help?
Do you have a question about the MAT14CS and is the answer not in the manual?