Removing the right control panel

Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1
Follow the safety guidelines listed in the Safety instructions section.
2
Follow the procedure listed in the Before working inside your system section.
3
Keep the T15 Torx screwdriver ready.
CAUTION:
The right control panel module is connected to the backplane using a Zero Insertion Force (ZIF) connector. To prevent
damage to the right control panel cable, you must release the locking tab of the ZIF connector on the hard drive backplane
before removing or installing the right control panel cable. Do not use excessive force when removing the right control panel
module cable as it can damage the connectors.
Steps
1
Lift the locking tab on the right control panel cable connector to release the lock.
2
Disconnect the right control panel cable from the backplane.
3
Remove the screws securing the right control panel to the chassis.
4
Pull out the right control panel cable through the channel on the chassis.