Removing The Cooling Shroud - Dell DSS 2500 Owner's Manual

Table of Contents

Advertisement

Removing the cooling shroud

Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1
Follow the safety guidelines listed in the Safety instructions section.
2
Follow the procedure listed in the Before working inside your system section.
3
If connected, disconnect the cables from expansion card(s).
NOTE:
If required, close the expansion card latch on the cooling shroud to release the full length card.
4
If installed, remove the expansion card riser.
CAUTION:
Never operate your system with the air shroud removed. The system may get overheated quickly, resulting in
shutdown of the system and loss of data.
Step
Hold the sides of the cooling shroud and lift the cooling shroud away from the system.
Figure 13. Removing the cooling shroud (135 W processor)
1
cooling shroud
Installing and removing system components
59

Advertisement

Table of Contents
loading

Table of Contents