1

Safety instructions and recommendations

1.1

Safety

Operation
Electrical
In order to avoid the danger of an unexpected thermal circuit breaker reset, this appliance must not be
powered through an external switch, such as a timer, or be connected to a circuit which is regularly
switched on and off by the electricity provider.
Domestic water
The appliance is intended to be permanently connected to the domestic water mains network.
A disconnection device must be fitted to the fixed wiring in accordance with the installation rules.
7748661 - v04 - 01022022
Danger
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not be made by chil­
dren without supervision.
Important
Before any work on the appliance, carefully read all documents that accompany
the product. These documents are also available on our website. See the last
page.
Warning
Install the appliance in accordance with national rules on electrical installation.
If a power supply cable comes with the appliance and it turns out to be dam­
aged, it must be replaced by the manufacturer, its after-sales service or persons
with similar qualifications in order to avoid danger.
If the appliance is not wired in the factory, carry out the wiring according to the
wiring diagram described in the chapter Electrical Connections. See the Installa­
tion and Service Manual.
This appliance must be connected to the protective earthing.
Earthing must comply with the prevailing installation standards.
Earth the appliance before making any electrical connections.
Type and calibre of the protective equipment: refer to the "Recommended cable
cross-sections" chapter. See the Installation and Service Manual.
To connect the appliance to the electricity mains, refer to the "Electrical Connec­
tions" chapter. See the Installation and Service Manual.
Caution
Draining the domestic hot water tank:
1. Shut off the domestic cold water inlet.
2. Open a hot water tap in the installation.
3. Open a valve on the safety unit.
4. When the water stops flowing, the domestic hot water tank has been drained.
Caution
The pressure limiter device (safety valve or safety unit) must be regularly operat­
ed in order to remove limescale deposits and ensure that it is not blocked.
A pressure limiter device must be fitted to a discharge pipe.
As water may flow out of the discharge pipe, the pipe must be kept open to the
open air, in a frost-free environment, and at a continuous downward gradient.
A pressure reducer (not provided) is required when the supply pressure exceeds
80% of the pressure limiter device calibration and must be located upstream of
the appliance.
There must be no cut-off devices between the pressure limiter device and the
domestic hot water tank.
To ascertain the type, specifications and connection of the pressure limiter device,
refer to the chapter Connecting the domestic hot water circuit in the installation
and service manual.