Active Ping Check Configuration; Non Poe Model Cnge2+2Sms - Comnet CNGE2+2SMS Installation And Operation Manual

10/100/1000 mbps intelligent redundant ring gigabit switch with optional poe+
Hide thumbs Also See for CNGE2+2SMS:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL

Active Ping Check Configuration

Non PoE Model CNGE2+2SMS

The active ping check function allows the switch to check that a configured IP address is alive
on each of the RJ45 ports. If the specified IP address becomes unreachable then the switch will
perform the action selected in the Failure Action menu.
Label
Description
Enable
Select to enable the active ping check function
Interval
Active ping check interval in seconds
Remote IP
Configure IP addresses of remote device to ping
Failure action
Configure action to take upon failure
No Action - No action taken
SNMP Trap - Issue an SNMP trap
Power Down - Turn off the RJ45 port
PwrDwn & Trap - Issue an SNMP trap and then turn off the RJ45 port
Retries
Number of times to retry the ping check on failure before proceeding with the selected
failure action.
TECH SUPPORT: 1.888.678.9427
Active Ping Check configuration interface
CNGE2+2SMS[POE][HO]
INS_CNGE2+2SMS_REV– 02/19/13 PAGE 31