DIP Switches

The CNGE2+2SMS's dip switches configure switch features. The DIP Switches are numbered from
left to right when viewing the side of the Switch with the backplate on the bottom and the power
connections on the left. If "Web Management Enable" is selected in the management software
under System Settings, the DIP switch settings will be overridden by any settings made in the
browser interface.
Switch Function Listing
The switch functions may be set individually or may be combined in the following order to perform
enhanced functions above the individual operation. The table below describes the operation of the
switch functions. This same table is also available in the help menu of the system webpage.
Summary of the switch configurations (in order of switch priority)
RSTP
SMS MUX
(Switch 1)
(Switch 2)
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
TECH SUPPORT: 1.888.678.9427
DIP Switch
Position
Description
1
RSTP enable (down = disabled, up enabled)
2
Port SMS Mux
3
Root Bridge Select
4
Redundant SFP mode
5
IGMP enable
6
SFP Port 3 speed. Up: 1000M/Down: 100M
7
SFP Port 4 speed. Up: 1000M/Down: 100M
ROOT BR
R SFP
(Switch 3)
(Switch 4)
OFF
ON
OFF
OFF
OFF
Resulting Mode
OFF
RSTP
OFF
RSTP
OFF
SMS
SMS with
ON
Redundant SFP
ON
Redundant SFP
CNGE2+2SMS[POE][HO]
Comment
All ring configurations
RSTP this bridge set to root
Port4 is uplink (traffic from
ports 1-3 is sent only to port 4)
Fiber fail over
with Port1 and Port2 isolation
Fiber fail over
Port 4 is primary port
INS_CNGE2+2SMS_REV– 02/19/13 PAGE 14