Variable name
Meaning
_EIP_TargetNodeErr
Target Node Error
[255]
Information
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Function
NX-series CPU Units: Indicates that the
connection for the Registered Target
Node Information for CIP communications
1 was not established or that an error
occurred in the target Controller.
The array elements are valid only when
the Registered Target Node Information is
TRUE.
Array[x] is TRUE:
A connection was not normally estab-
lished with the target node for a target
node ID of x
(the Registered Target Node Informa-
tion is TRUE and the Normal Target
Node Information is FALSE),
or a connection was established with
the target node but an error occurred in
the target Controller.
Array[x] is FALSE:
The target node is not registered for a
target node ID of x (the Registered Tar-
get Node Information is FALSE), or a
connection was normally established
with the target node (the Registered
Target Node Information is TRUE and
the Normal Target Node Information is
TRUE).
An error occurred in the target Control-
ler (the Target PLC Error Information is
TRUE).
NJ-series CPU Units: Indicates that the
connection for the Registered Target
Node Information was not established or
that an error occurred in the target Con-
troller.
The array elements are valid only when
the Registered Target Node Information is
TRUE.
Array[x] is TRUE:
A connection was not normally estab-
lished with the target node for a target
node ID of x
(the Registered Target Node Informa-
tion is TRUE and the Normal Target
Node Information is FALSE),
or a connection was established with
the target node but an error occurred in
the target Controller.
Array[x] is FALSE:
The target node is not registered for a
target node ID of x (the Registered Tar-
get Node Information is FALSE), or a
connection was normally established
with the target node (the Registered
Target Node Information is TRUE and
the Normal Target Node Information is
TRUE).
An error occurred in the target Control-
ler (the Target PLC Error Information is
TRUE).
Range of
Data type
values
ARRAY
TRUE or
[0..255] OF
FALSE
BOOL
Reference
page 3-56
3
3-27