Variable name
_EIP2_TargetNodeErr [255]
Meaning
CIP Communications2 Target Node Error Infor-
mation
Function
Indicates that the connection for the Registered Target Node Information for CIP communications 2 was not estab-
lished or that an error occurred in the target Controller.
The array elements are valid only when the Registered Target Node Information is TRUE.
Array[x] is TRUE: A connection was not normally established with the target node for a target node ID of x (the Regis-
tered Target Node Information is TRUE and the Normal Target Node Information is FALSE), or a connection was
established with the target node but an error occurred in the target Controller.
Array[x] is FALSE: The target node is not registered for a target node ID of x (the Registered Target Node Informa-
tion is FALSE), or a connection was normally established with the target node (the Registered Target Node Infor-
mation is TRUE and the Normal Target Node Information is TRUE). An error occurred in the target Controller (the
Target PLC Error Information is TRUE).
Note You can use this system-defined variable only for the NX701 CPU Units.
Data type
ARRAY [0..255] OF BOOL
R/W access
R
Usage in user pro-
Possible.
gram
Variable name
_EIP_NTPResult
Meaning
NTP Last Operation Time
Function
Gives the last time that NTP processing ended normally.
The time that was obtained from the NTP server is stored when the time is obtained normally.
The time is not stored if it is not obtained from the NTP server normally.
Note Do not use this variable in the user program. There may be a delay in updating it. Use this variable only to
access status through communications from an external device.
Data type
Structure: _sNTP_RESULT
Members: DATE_AND_TIME
R/W access
R
Usage in user pro-
Not possible.
gram
Variable name
_EIP_NTPResult
Meaning
NTP Operation Result
Function
This variable shows if the NTP operation ended normally.
TRUE: Indicates an NTP normal end.
FALSE: Indicates that NTP operation ended in an error or has not been executed even once.
Note Do not use this variable in the user program. There may be a delay in updating it. Use this variable only to
access status through communications from an external device.
Data type
BOOL
R/W access
R
Usage in user pro-
Not possible.
gram
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
You can read the contents of this variable with the GetNTPStatus instruction.
instructions
Retained
Not retained.
Related
You can read the contents of this variable with the GetNTPStatus instruction.
instructions
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Member name
.ExecTime
Global/local
Global
Range of values
Depends on data type.
Network Publish
Published.
Member name
.ExecNormal
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
3
3-57