Variable name
_EIP2_LanHwErr
Meaning
Port2 Communications Controller Error
Function
Indicates that a communications controller failure occurred on the communications port 2.
TRUE: Failure
FALSE: Normal
Note You can use this system-defined variable only for the NX701 CPU Units.
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP_EtnCfgErr
Meaning
Basic Ethernet Setting Error
Function
NX-series CPU Units: Indicates that the Ethernet communications speed setting (Speed/Duplex) for the communi-
cations port 1 is incorrect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
NJ-series CPU Units: Indicates that the Ethernet communications speed setting (Speed/Duplex) is incorrect. Or, a
read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP1_EtnCfgErr
Meaning
Port1 Basic Ethernet Setting Error
Function
Indicates that the Ethernet communications speed setting (Speed/Duplex) for the communications port 1 is incor-
rect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined variable only for NX-series CPU Units.
Data type
BOOL
R/W access
R
Usage in user program
Possible.
Variable name
_EIP2_EtnCfgErr
Meaning
Port2 Basic Ethernet Setting Error
Function
Indicates that the Ethernet communications speed setting (Speed/Duplex) for the communications port 2 is incor-
rect. Or, a read operation failed.
TRUE: Setting incorrect or read failed
FALSE: Normal
Note You can use this system-defined variable only for the NX701 CPU Units.
Data type
BOOL
R/W access
R
Usage in user program
Possible.
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Retained
Not retained.
Related
---
instructions
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.