Comm. And Options; Smart Logic - Danfoss FC 51 Series Programming Manual

Hide thumbs Also See for FC 51 Series:
Table of Contents

Advertisement

Parameter Lists

5.1.13 8-** Comm. and Options

Parameter
Number
8-01
Control Site
8-02
Control Word Source
8-03
Control Word Timeout Time
8-04
Control Word Timeout Function
8-06
Reset Control Word Timeout
8-30
Protocol
8-31
Address
5
5
8-32
FC Port Baud Rate
8-33
FC Port Parity
8-35
Minimum Response Delay
8-36
Max Response Delay
8-43
FC Port PCD Read Configuration
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-94
Bus feedback 1
Table 5.16

5.1.14 13-** Smart Logic

Parameter
Number
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-20
SL Controller Timer
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-51
SL Controller Event
13-52
SL Controller Action
Table 5.17
60
VLT
Parameter Description
Parameter Description
MG02C602 - VLT
®
Micro Drive FC 51 Programming Guide
Default Value
[0] Digital and ctrl.word
All set-ups
[1] FC RS485
All set-ups
1 s
1 set-up
[0] Off
1 set-up
[0] No function
1 set-up
[0] FC
1 set-up
1
1 set-up
[2] 9600 Baud
1 set-up
[0] Even Parity 1 Stop Bit
1 set-up
0.01 s
1 set-up
5 s
1 set-up
0
1 set-up
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
0
All set-ups
Default Value
[0] Off
1 set-up
[39] Start command
1 set-up
[40] Drive stopped
1 set-up
[0] Do not reset
1 set-up
[0] Disabled
1 set-up
[1] ApproxEqual
1 set-up
0
1 set-up
0 s
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
[0] False
1 set-up
[0] False
1 set-up
[0] Disabled
1 set-up
®
is a registered Danfoss trademark
Change During
2 Setup
Operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Change During
2 Setup
Operation
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Conversi
Type
on Index
-
Uint8
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
-
Uint8
-
Uint8
-3
Uint16
-3
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
Conversi
Type
on Index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-1
Int32
-1
Uint32
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt micro driveVlt micro drive fc 51

Table of Contents