Troubleshooting
No. Description
51
AMT check U
52
AMT low I
53
AMT motor too big
54
AMT motor too small
55
AMT Parameter out of range
59
Current limit
63
Mechanical Brake Low
80
Drive Initialized to Default Value
84
The connection between drive and LCP is lost
85
Button disabled
86
Copy fail
87
LCP data invalid
6
6
88
LCP data not compatible
89
Parameter read only
90
Parameter database busy
91
Parameter value is not valid in this mode
92
Parameter value exceeds the min/max limits
Table 6.1 Alarm/Warning Code List
(X) Dependent on parameter
A trip is the action when an alarm has appeared. The trip
will coast the motor and can be reset by pressing [Reset]
or make a reset by a digital input (parameter group 5-1*
[1]). The original event that caused an alarm cannot
damage the frequency converter or cause dangerous
conditions. A trip lock is an action when an alarm occurs,
which may cause damage to frequency converter or
connected parts. A trip lock situation can only be reset by
a power cycling.
LED indication
Warning
Alarm
Table 6.2
The alarm words, warning words and extended status
words can be read out via serial bus or optional fieldbus
for diagnosis. See also 16-90 Alarm Word, 16-92 Warning
Word and 16-94 Ext. Status Word.
64
VLT
and I
nom
nom
nom
yellow
flashing red
MG02C602 - VLT
®
Micro Drive FC 51 Programming Guide
Warning
Alarm
Trip Lock
X
X
X
X
X
X
X
X
®
is a registered Danfoss trademark
Error
Parameter
Reference
X
X
X
X
X
X
X
X
X