Analog In/Out; Controllers - Danfoss FC 51 Series Programming Manual

Hide thumbs Also See for FC 51 Series:
Table of Contents

Advertisement

Parameter Lists

5.1.11 6-** Analog In/Out

Parameter
Parameter Description
Number
6-00
Live Zero Timeout Time
6-01
Live Zero TimeoutFunction
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
Terminal 53 Low Ref./Feedb.
6-14
Value
Terminal 53 High Ref./Feedb.
6-15
Value
6-16
Terminal 53 Filter Time Constant
6-19
Terminal 53 mode
6-22
Terminal 60 Low Current
6-23
Terminal 60 High Current
Terminal 60 Low Ref./Feedb.
6-24
Value
Terminal 60 High Ref./Feedb.
6-25
Value
6-26
Terminal 60 Filter Time Constant
6-80
LCP Potmeter Enable
6-81
LCP potentiometer Low Ref.
6-82
LCP potentiometer High Ref.
6-90
Terminal 42 Mode
6-91
Terminal 42 Analog Output
6-92
Terminal 42 Digital Output
6-93
Terminal 42 Output Min Scale
6-94
Terminal 42 Output Max Scale
Table 5.14

5.1.12 7-** Controllers

Parameter
Parameter Description
Number
7-20
Process CL Feedback 1 Resource
Process PI Normal/ Inverse
7-30
Control
7-31
Process PI Anti Windup
7-32
Process PI Start Speed
7-33
Process PI Proportional Gain
7-34
Process PI Integral Time
7-38
Process PI Feed Forward Factor
7-39
On Reference Bandwidth
Table 5.15
®
VLT
Micro Drive FC 51 Programming Guide
Default Value
10 s
[0] Off
0.07 V
10 V
0.14 mA
20 mA
0
50
0.01 s
[0] Voltage mode
0.14 mA
20 mA
0
50
0.01 s
1
0
50
[0] 0-20 mA
[0] No operation
[0] No operation
0%
100%
Default Value
[0] No function
[0] Normal
[1] Enabled
0 Hz
0.01
9999 s
0%
5%
®
MG02C602 - VLT
is a registered Danfoss trademark
Change During
2 Setup
Operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Change During
2 Setup
Operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conversi
Type
on Index
0
Uint8
-
Uint8
-2
Uint16
-2
Uint16
-2
Uint16
-2
Uint16
5
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-2
Uint16
-2
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
Conversi
Type
on Index
-
Uint8
-
Uint8
-
Uint8
-1
Uint16
-2
Uint16
-2
Uint32
0
Uint16
0
Uint8
59
5