Tektronix WFM5200 Technical Reference page 59

Waveform monitor specifications and performance verification
Hide thumbs Also See for WFM5200:
Table of Contents

Advertisement

WFM5200 Waveform Monitor Specifications and Performance Verification
12. Set the waveform monitor to the factory presets. (See page 32, Restore the
Factory Presets.)
13. Short pins 1 and 10 together on the remote cable.
14. Preset A1 should be restored so that a picture is displayed in tile 1.
15. Short pins 1 and 11 together on the remote cable.
16. Preset A2 should be restored so that a picture is displayed in tile 2.
17. Short pins 1 and 12 together on the remote cable.
18. Preset A3 should be restored so that a picture is displayed in tile 3.
19. Short pins 1 and 13 together on the remote cable.
20. Preset A4 should be restored so that a picture is displayed in tile 4.
21. Short pins 1 and 14 together on the remote cable. Preset A5 should be restored
with a picture in tiles 1 and 4.
22. Short pins 1 and 15 together on the remote cable. Preset A6 should be restored
with a picture in tiles 2 and 4.
23. Record Pass or Fail for Activate Preset in the test record.
24. Restore saved presets from the USB flash memory device (if saved before
this procedure).
Ground Closure Alarm Test.
25. Connect a 525/270 color bar signal from the DVG7 to the SDI 1A input.
26. Restore the Factory Preset. (See page 32, Restore the Factory Presets.)
27. On a 15-pin, male HD-15 connector, solder wires or strip back insulation to
gain access to pins 1 and 9 (pin 1 is a ground and pin 9 is the ground closure
output signal).
NOTE.
You can use the test cable prepared for the previous step.
28. Connect the HD-15 connector to the REMOTE connector on the waveform
monitor.
29. Press the CONFIG button to display the CONFIG menu.
30. Select Alarms > SDI Input, then press the SEL button.
31. Use the arrow keys to move the selection highlighting to the Ground Closure
column of the SDI Input Missing row, and then press SEL to put an X in
the box. This instructs the waveform monitor to assert the ground closure if
the input is not present.
Incoming Inspection
43

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WFM5200 and is the answer not in the manual?

Table of Contents