Tektronix WFM5200 Series Release Notes
Tektronix WFM5200 Series Release Notes

Tektronix WFM5200 Series Release Notes

Waveform monitors/waveform rasterizers
Hide thumbs Also See for WFM5200 Series:

Advertisement

WFM5200 Series Waveform Monitors
xx
WVR5200 Series Waveform Rasterizers
ZZZ
Release Notes
This document supports software Version 2.9.x.
www.tek.com
*P077080202*
077-0802-02

Advertisement

loading
Need help?

Need help?

Do you have a question about the WFM5200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix WFM5200 Series

  • Page 1 WFM5200 Series Waveform Monitors WVR5200 Series Waveform Rasterizers Release Notes This document supports software Version 2.9.x. www.tek.com *P077080202* 077-0802-02...
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 3: Release Notes

    The new HDR features and functions are described on the following pages. NOTE. Option PROD is required to access HDR features. WFM5200 Series and WVR5200 Series Release Notes...
  • Page 4 Left / Right arrow keys to toggle the vertical scale of the graticule between NITS, STOPS, REFLECTANCE, CODE VALUE, and PERCENT. The selected scale is shown at the bottom of the display. (See Figure 3.) Figure 1: Waveform display pop-up menu showing the Dynamic Range selection WFM5200 Series and WVR5200 Series Release Notes...
  • Page 5 ST2084(2K). This graticule uses the ST 2084 curve with a maximum value of 2000 Nits using narrow range. ST2084(4K). This graticule uses the ST 2084 curve with a maximum value of 4000 Nits using narrow range. WFM5200 Series and WVR5200 Series Release Notes...
  • Page 6 ST2084(1K) Full. This graticule uses the ST 2084 curve with a maximum value of 1000 Nits using full range. ST2084(10K) Full. This graticule uses the ST 2084 curve with a maximum value of 10000 Nits using full range. WFM5200 Series and WVR5200 Series Release Notes...
  • Page 7 HDR graticule to be used by the Waveform display: HLG(1000), HLG(1200), ST2084(1K), ST2084(2K), ST2084(5K), or ST2084(10K). Figure 2: CONFIG menu showing the SDI HDR Waveform Graticule selection WFM5200 Series and WVR5200 Series Release Notes...
  • Page 8 Variable Gain will be enabled by default to facilitate the Zoom mode function. Voltage cursors. When HDR or HDR Full mode is selected as the Dynamic Range setting, the mV voltage measurement cursors are replaced by a set of Nits measurement cursors. WFM5200 Series and WVR5200 Series Release Notes...
  • Page 9 HDR Full settings and produces HDR zebra highlights in the picture for large areas of the trace that exceeding 100 Nits. Figure 4: CONFIG menu showing the Picture Brightup on Luma/Specular Gamut Error selection WFM5200 Series and WVR5200 Series Release Notes...
  • Page 10 Tile 2: Waveform display with the HDR zoom mode enabled. Tile 3: Picture display with specular highlighting enabled. Tile 4: Video Session display. Figure 5: Typical HDR monitoring setup for ST2084(10K) For more information visit: www.tek.com/waveform-monitor/wfm-wvr5000–series WFM5200 Series and WVR5200 Series Release Notes...
  • Page 11: General Limitations

    files saved on the USB device if you do not use the “Unmount” feature. If there are more than 32 files saved in a Presets directory on the USB device, you can only view the first 32 files. WFM5200 Series and WVR5200 Series Release Notes...
  • Page 12 The Web browser applet will not resize when running in some versions of the Netscape browser and in some non-Windows Operating Systems (for example, Solaris). We recommend using Java Runtime Engine (JRE) Version 1.6 or above. WFM5200 Series and WVR5200 Series Release Notes...