GENERIC TERMS AND ABBREVIATIONS

Generic term/
abbreviation
GX Developer
RWr
RWw
RX
RY
SB
SW
Safety master station on
CC-Link Safety
Remote station on
CC-Link Safety
Safety remote I/O station
on CC-Link Safety
Standard remote I/O
station on CC-Link Safety
Remote I/O station on
CC-Link Safety
Remote device station on
CC-Link Safety
Safety station on CC-Link
Safety
Master station (safety
station) on CC-Link IE
Field Network
Local station (safety
station) on CC-Link IE
Field Network
Slave station on CC-Link
IE Field Network
Safety station on CC-Link
IE Field Network
CC-Link Safety master
module
CC-Link Safety remote I/O
module
CC-Link IE Field Network
master/local module (with
safety functions)
Safety main base unit
A
- 16
Unless otherwise specified, this manual uses the following generic terms and abbrevia-
tions. When a clear indication of target model name is required, the module name is indi-
cated.
Generic product name for models SWnD5C-GPPW, SWnD5C-GPPW-A, SWnD5C-GPPW-V,
and SWnD5C-GPPW-VA
Remote register (Read area for CC-Link Safety and CC-Link IE Field Network)
Remote register (Write area for CC-Link Safety and CC-Link IE Field Network)
Remote input (for CC-Link Safety and CC-Link IE Field Network)
Remote output (for CC-Link Safety and CC-Link IE Field Network)
Link special relay (for CC-Link Safety and CC-Link IE Field Network)
Link special register (for CC-Link Safety and CC-Link IE Field Network)
Station that controls CC-Link Safety.
One station is required in a system.
Generic term for a safety remote I/O station, a standard remote I/O station, and a remote device
station on CC-Link Safety. This station is controlled by the safety master station on CC-Link
Safety.
Remote station on CC-Link Safety, which exchanges only bit data.
Compatible with the safety-related system.
Remote station on CC-Link Safety, which exchanges only bit data.
Not compatible with the safety-related system.
Generic term for a safety remote I/O station and a standard remote I/O station on CC-Link
Safety
Remote station on CC-Link Safety, which exchanges bit data and word data.
Not compatible with the safety-related system.
Generic term for stations on CC-Link Safety, which perform safety communication
Station that controls the entire CC-Link IE Field Network. Only one station can be used in a
network.
This station can perform cyclic transmission and transient transmission with all stations on
CC-Link IE Field Network. The station can also perform safety communication with another
safety station on the same network.
This station can perform cyclic transmission and transient transmission with the master station
and other local stations on CC-Link IE Field Network. The station can also perform safety
communication with another safety station on the same network. The station is controlled by
programs in the CPU module or other equivalent modules on the station.
Generic term for stations other than a master station on CC-Link IE Field Network: local station,
remote I/O station, remote device station, and intelligent device station
Generic term for stations on CC-Link IE Field Network, which perform safety communication
and standard communication
Abbreviation for the QS0J61BT12 CC-link Safety system master module
Abbreviation for the QS0J65BTS2-8D, QS0J65BTS2-4T and QS0J65BTB2-12DT CC-Link
Safety system remote I/O module
Abbreviation for the QS0J71GF11-T2 CC-Link IE Field Network master/local module
Abbreviation for the QS034B(-E) type safety main base unit