Cable Requirements; Table 11. Twisted Pair Cable Requirements At 10 Or 100Mbps - Allied Telesis IE210L Series Installation Manual

Industrial gigabit ethernet switches
Table of Contents

Advertisement

Appendix A: Technical Specifications

Cable Requirements

Table 11. Twisted Pair Cable Requirements At 10 or 100Mbps

Cable type
Cat 3: Standard TIA/EIA 568-
B-compliant Category 3
shielded or unshielded cabling
with 100 ohm impedance and
a frequency of 16 MHz
Cat 5: Standard TIA/EIA 568-
A-compliant Category 5
shielded or unshielded cabling
with 100 ohm impedance and
a frequency of 100 MHz
Cat 5e: Standard TIA/EIA 568-
B-compliant Enhanced
Category 5 (Cat 5e) shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz
Cat 6 or 6a: Standard TIA/EIA
568-B-compliant Category 6
or 6a shielded cabling
66
Cable requirements for the 10BASE-T/100BASE-TX/1000BASE-T ports
operating at 10, 100, or 1000 Mbps are in Table 11.
.
10Mbps
Non
PoE
PoE
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Note
The twisted pair ports on the switch feature auto-MDI when
operating at 10, 100, or 1000 Mbps. A port is configured as MDI or
MDIX when it is connected to an end node. Consequently, you can
use a straight-through twisted pair cable when connecting any type
of network device to a port on the switch.
100Mbps
PoE
Non
PoE
+
PoE
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1000Mbps
PoE
Non
PoE
+
PoE
No
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
PoE
+
No
No
Yes
Yes