Chapter 2: Installation

Start a Local Management Session

50
This procedure requires a terminal or a terminal emulator program and the
management cable that comes with the switch. To start a local
management session on the IE210L Series switch, perform the following
procedure:
1. Connect the RJ45 connector on the management cable to the console
port on the front panel of the switch. Refer to Figure 18.
Figure 18. Connect Management Cable to Console Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. If you have not already done so, power up the switch as described in
"Power ON the Switch" on page 47.