6 How to program the adjustable frequency
drive
Function Set-ups parameters
The Function Set-ups parameters are grouped in the following way:
Q3-10 Adv. Motor Settings
Motor Thermal Protection
par.1-90
par.1-93
Thermistor Source
Automatic Motor Adapta-
par.1-29
tion (AMA)
Switching Frequency
par.14-01
par.4-53
Warning Speed High
Q3-20 Digital Reference
Minimum Reference
par.3-02
Maximum Reference
par.3-03
par.3-10
Preset Reference
6
Terminal 29 Digital Input
par. 5-13
par.5-14
Terminal 32 Digital Input
Terminal 33 Digital Input
par. 5-15
Q3-30 Single Zone Int. Setpoint
par.1-00
Configuration Mode
Reference/Feedback Unit
par. 20-12
par. 20-13
Minimum Reference/Feedb.
Maximum Reference/Feedb.
par. 20-14
Terminal 54 Low Current
par. 6-22
par.6-24
Terminal 54 Low Ref./Feedb. Value
Terminal 54 High Ref./Feedb. Value
par.6-25
par.6-26
Terminal 54 Filter Time Constant
Terminal 54 Live Zero
par.6-27
Live Zero Timeout Time
par.6-00
par.6-01
Live Zero Timeout Function
Setpoint 1
par.20-21
par.20-81
PID Normal/ Inverse Control
PID Start Speed [RPM]
par. 20-82
PID Start Speed [Hz]
par. 20-83
PID Proportional Gain
par.20-93
PID Integral Time
par.20-94
par. 20-70
Closed-loop Type
Tuning Mode
par. 20-71
par. 20-72
PID Output Change
Minimum Feedback Level
par. 20-73
Maximum Feedback Level
par. 20-74
par. 20-79
PID Auto Tuning
6-12
Q3-1 General Settings
Q3-11 Analog Output
Q3-12 Clock Settings
Terminal 42 Output
par.6-50
par.0-70
par.6-51
Terminal 42 Output Min
par.0-71
Scale
Terminal 42 Output Max
par.6-52
par.0-72
Scale
par.0-74
par.0-76
par.0-77
Q3-2 Open-loop Settings
Q3-3 Closed-loop Settings
Q3-31 Single Zone Ext. Setpoint
par.1-00
Configuration Mode
Reference/Feedback Unit
par. 20-12
par. 20-13
Minimum Reference/Feedb.
Maximum Reference/Feedb.
par. 20-14
Terminal 53 Low Voltage
par.6-10
par.6-11
Terminal 53 High Voltage
Terminal 53 Low Current
par. 6-12
par. 6-13
Terminal 53 High Current
Terminal 53 Low Ref./Feedb. Value
par.6-14
Terminal 53 High Ref./Feedb. Value
par.6-15
par. 6-22
Terminal 54 Low Current
Terminal 54 Low Ref./Feedb. Value
par.6-24
par.6-25
Terminal 54 High Ref./Feedb. Value
Terminal 54 Filter Time Constant
par.6-26
Terminal 54 Live Zero
par.6-27
Live Zero Timeout Time
par.6-00
Live Zero Timeout Function
par.6-01
par.20-81
PID Normal/ Inverse Control
PID Start Speed [RPM]
par. 20-82
par. 20-83
PID Start Speed [Hz]
PID Proportional Gain
par.20-93
PID Integral Time
par.20-94
par. 20-70
Closed-loop Type
Tuning Mode
par. 20-71
par. 20-72
PID Output Change
Minimum Feedback Level
par. 20-73
Maximum Feedback Level
par. 20-74
par. 20-79
PID Auto Tuning
MG.11.A9.22 - VLT
VLT
Q3-13 Display Settings
Set Date and Time
par.0-20
Date Format
par.0-21
Time Format
par. 0-22
DST/Summertime
par. 0-23
DST/Summertime Start
par. 0-24
DST/Summertime End
par.0-37
par.0-38
par.0-39
Q3-21 Analog Reference
Minimum Reference
par.3-02
Maximum Reference
par.3-03
par.6-10
Terminal 53 Low Voltage
Terminal 53 High Voltage
par.6-11
par. 6-12
Terminal 53 Low Current
Terminal 53 High Current
par. 6-13
Terminal 53 Low Ref./Feedb. Value
par.6-14
par.6-15
Terminal 53 High Ref./Feedb. Value
Q3-32 Multi Zone / Adv
par.1-00
Configuration Mode
Reference 1 Source
par.3-15
par.3-16
Reference 2 Source
Feedback 1 Source
par.20-00
Feedback 1 Conversion
par.20-01
par. 20-02
Feedback 1 Source Unit
Feedback 2 Source
par.20-03
par.20-04
Feedback 2 Conversion
Feedback 2 Source Unit
par. 20-05
Feedback 3 Source
par.20-06
par.20-07
Feedback 3 Conversion
Feedback 3 Source Unit
par. 20-08
par. 20-12
Reference/Feedback Unit
Minimum Reference/Feedb.
par. 20-13
Maximum Reference/Feedb.
par. 20-14
Terminal 53 Low Voltage
par.6-10
Terminal 53 High Voltage
par.6-11
par. 6-12
Terminal 53 Low Current
Terminal 53 High Current
par. 6-13
par.6-14
Terminal 53 Low Ref./Feedb. Value
Terminal 53 High Ref./Feedb. Value
par.6-15
Terminal 53 Filter Time Constant
par.6-16
par.6-17
Terminal 53 Live Zero
Terminal 54 Low Voltage
par.6-20
par.6-21
Terminal 54 High Voltage
Terminal 54 Low Current
par. 6-22
Terminal 54 High Current
par. 6-23
par.6-24
Terminal 54 Low Ref./Feedb. Value
Terminal 54 High Ref./Feedb. Value
par.6-25
par.6-26
Terminal 54 Filter Time Constant
Terminal 54 Live Zero
par.6-27
Live Zero Timeout Time
par.6-00
par.6-01
Live Zero Timeout Function
Warning Feedback Low
par.4-56
par.4-57
Warning Feedback High
Feedback Function
par.20-20
Setpoint 1
par.20-21
Setpoint 2
par.20-22
PID Normal/ Inverse Control
par.20-81
par. 20-82
PID Start Speed [RPM]
PID Start Speed [Hz]
par. 20-83
PID Proportional Gain
par.20-93
PID Integral Time
par.20-94
®
is a registered Danfoss trademark
®
HVAC Drive Instruction Manual
Display Line 1.1 Small
Display Line 1.2 Small
Display Line 1.3 Small
Display Line 2 Large
Display Line 3 Large
Display Text 1
Display Text 2
Display Text 3
Need help?
Do you have a question about the VLT and is the answer not in the manual?