AKD PDMM User Guide | 17.11   Mains Supply Connection (X3, X4)

17.11 Mains Supply Connection (X3, X4)

17.11.1 Three Phase connection (all AKD PDMM types)

Directly to 3-phase supply network, supply networks => p. 1
l
Filtering for AKD PDMM-xzzz06 to be provided by the user.
l
Fusing (such as fusible cut-outs) to be provided by the user .
l
AKD PDMM-x02406 & AKD PDMM-xzzz07 (X3)
Pin
Signal
3
-DC
4
+DC (+RB)
AKD PDMM-x00106x00306 to AKD PDMM-
x00606 (X3)
Pin
Signal
4
L1
5
L2
6
L3
7
PE
Description
DC-Link Bus negative
DC-Link Bus positive
Description
Line 1
Line 2
Line 3
Protective Earth