Remote Control
Arguments
for
Command
Command
or
(Instruction
Parameter
Response
Code and
Type
to Query
qualifier)
Total New
N/A
2 bytes,
Alarms
numerical
(Retrieve
Number of
unread
Stored
Alarms)
Retrieve
N/A
10 bytes,
Serial
alpha
Number
numerical
Retrieve
N/A
20 bytes,
Equipment
alpha
Type
numerical
Circuit
CID=
24 bytes,
Identification
alpha
Message
numerical
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
CSAT returns the number of Stored Events which
remain unread, in the form xx. Note: This means unread
over the remote control – viewing the stored events
from the front panel of the modem does not affect this
value.
Example reply: TNA=18'cr''lf'
Query only.
Used to Query the units 6 digit serial number.
Slave returns its S/N, in the form Cxxxxxxxxx
Example: RSN=C001234567'cr''lf'
Query only.
CSAT returns a string indicated the Model Number and
the value of internal software revision installed
Example: RET=CSAT-5060/050 V1.02'cr''lf'
Command or Query.
Sets or queries the user-defined Circuit ID string, which
is a fixed length of 24 characters.
Valid characters include:
Space ( ) * + _ , . / 0-9 A-Z
Response to
Command
(Slave to Master)
N/A
N/A
N/A
CID= (message ok)
CID? (received ok,
but invalid
arguments found)
A-14
MN/CSAT506025.IOM
Query
(Instruction
Response to query
code and
(Slave to Master)
qualifier)
TNA?
TNA=xx (see description for details
of arguments)
RSN?
RSN=Cxxxxxxxxx (see description
for details of arguments)
RET?
RET=x....x (see description for
details of arguments)
CID?
CID=x....x (see description for
details of arguments)