Comtech EF Data CSAT-5060 Installation And Operation Manual page 102

C-band transceiver 5 to 25 watt
Table of Contents

Advertisement

5 to 25 Watt C-Band Transceiver
Remote Control
Arguments
for
Command
Command
or
(Instruction
Parameter
Response
Code and
Type
to Query
qualifier)
Concise
N/A
31 bytes,
Configuration
alpha
Status
numerical
Concise LNA
N/A
4 bytes,
Status
alpha
numerical
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the Configuration status of the CSAT
Example: CCS=uuuu.udddd.daa.aabb.bbotamrncfx'cr''lf'
where:
uuuu.u = TX frequency
dddd.d = RX frequency
aa.aa = TX attenuation
bb.bb = RX attenuation
o = online status, 0 = OFFLINE, 1 = ONLINE
t = transmitter status, 0 = OFF, 1 = ON
a = amplifier status, 0 = OFF, 1 = ON
m = TX mute status, 0 = Unmuted, 1 = Muted
r = receiver status, 0 = OFF, 1 = ON
n = RX mute status, 0 = Unmuted, 1 = Muted
c = cold start, 0 = Disabled, 1 = Enabled
f = auto fault recover, 0 = Disabled, 1 = Enabled
x = external reference present, 0 = NO, 1 = YES
Query only.
Used to Query the LNA status of the CSAT
Example: CLS=abbc'cr''lf'
where:
a = LNA Current 0=OFF, 1=ON
bb = Current window in %
c = LNA Fault Logic 0=OFF, 1=ON
Response to
Command
(Slave to Master)
N/A
N/A
A-18
MN/CSAT506025.IOM
Query
(Instruction
Response to query
code and
(Slave to Master)
qualifier)
CCS?
CCS=x....x (see description for
details of arguments)
CLS?
CLS=x....x (see description for
details of arguments)
Revision 1