Comtech EF Data CSAT-5060 Installation And Operation Manual page 94

C-band transceiver 5 to 25 watt
Table of Contents

Advertisement

5 to 25 Watt C-Band Transceiver
Remote Control
Arguments
for
Command
Command
or
(Instruction
Parameter
Response
Code and
Type
to Query
qualifier)
LNA Fault
LFL=
1 byte,
Logic
value of 0,1
Calibrate
CAL=
None
LNA Current
LNA Current
LCW=
2 bytes,
Window
numerical
External
XRF=
1 byte,
Reference
value of 0,1
Fault Logic
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Command or Query.
LFL controls whether or not the Summary Fault Relay
(SFR)
is affected by the LNA Current window monitor, where:
0 = A LNA Current fault does not effect the SFR,
1 = A LNA Current fault will effect the SFR.
Example: LFL=1
Command only.
This command is used to set the calibration point for
the LNA current alarm feature.
Example: CAL=
Command or Query.
LNA Current Monitor Window, this command allows the
user to set the alarm window in ± % of the calibrated
LNA current. Valid inputs are 20 to 50 in increments of
1%. In addition, setting the value to 99 disables the
alarm function.
Example: LCW=30, set the alarm window at ± 30%.
Command or Query.
XRF controls whether or not the Software monitors the
external reference source. If enabled and no source is
present a fault will be reported.
0 = Ext Reference not monitored
1 = Ext Reference is monitored and the lock state
reported.
Example: XRF=1
Response to
Command
(Slave to Master)
LFL= (message ok)
LFL? (received ok,
But invalid
arguments found)
CAL= (message ok)
LCW= (message ok)
LCW? (received ok,
but invalid
arguments found)
XRF= (message ok)
XRF? (received ok,
but invalid
arguments found)
A-10
MN/CSAT506025.IOM
Query
(Instruction
Response to query
code and
(Slave to Master)
qualifier)
LFL?
LFL=x
(same format as command
arguments)
N/A
N/A
LCW?
LCW=xx
(same format as command
arguments)
XRF?
XRF=x
(same format as command
arguments)
Revision 1