Set RTC
TIM=
6 bytes,
Time
numerical
Clear All
CAA=
None
Stored
Alarms
Re-Initialize
IAP=
None
Retrieved
Alarms Point
List New
N/A
145 bytes
Alarms
(Retrieve
next 5
unread
Stored
Alarms)
Description of arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
A command in the form hhmmss, indicating the time
from midnight, where hh = hours, between 00 and 23;
mm = minutes, between 00 and 59, and ss = seconds,
between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes
and 59 seconds from midnight.
Command only
Instructs the slave to clear all Stored Events
This command takes no arguments.
Command only
Instructs the unit to zero the retrieved alarms pointer to
allow the user to retrieve the complete stored alarms
log.
Query only
CSAT returns the oldest 5 Stored Events that have not
yet been read over the remote control. Reply format:
Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body=
YYYYYYYYYY ZZ hhmmss,mmddyy
YYYYYYYYYY being the fault description.
ZZ being the alarm type.
FT = Fault
OK = Clear
IF = Information
If there are no new events, the CSAT will reply with
LNA*. Note: the CSAT incorporates a circular buffer
capable of holding 100 events/alarms.
Response to
Command
(Slave to Master)
TIM= (message ok)
TIM? (received ok,
but invalid
arguments found)
TIM* (message ok,
but not permitted in
current mode
CAA= (message ok)
IAP=(message ok)
N/A
A-13
MN/CSAT506025.IOM
Query
(Instruction
Response to query
code and
(Slave to Master)
qualifier)
TIM?
TIM=xxxxxx
(same format as command
arguments
N/A
N/A
N/A
N/A
LNA?
LNA=YY..ss
(see description for details of
arguments)