Table 4-8 M&C Signal Description (Connector J5) - Comtech EF Data CSAT-5060 Installation And Operation Manual

C-band transceiver 5 to 25 watt
Table of Contents

Advertisement

5 to 25 Watt Model C-Band Transceiver
Redundancy Installation
4.5.2.5 M&C I
NTERFACE
The J5 interface connector (19-pin) provides the communications and control signals between the
RSU-5060 and the customer M&C system.
Pin
Signal Name
A
RS485 RX+
B
RS485 RX-
C
RS485 TX+
D
RS485 TX-
E
B ONLINE CLOSED
F
n.c.
G
n.c.
H
n.c.
J
n.c.
K
IND/FLT COMMON
L
A FAULT OPEN
M
B FAULT OPEN
N
n.c.
P
RED AUTO/MAN
R
n.c.
S
A ONLINE CLOSED
T
GROUND
U
GROUND
V
SWITCH CMD
4.5.2.6 TX IF I
NTERFACES
The TX IF input signal is fed from the customers equipment to the RSU-5060 at connector J6.
The RSU-5060 contains a power splitter which feeds the IF input signal to both CSAT A and
CSAT B via the J7 and J8 connectors. The IF power at J7 and J8 will nominally be 3dBm less
than the IF input power at J6.
, J5
Table 4-8. M&C Signal Description (Connector J5)
Type
Pass-thru
Pass-thru
Pass-thru
Pass-thru
Output
Input
Output
Output
Input
Output
Passive
Passive
Input
, J6, J7,
AND
Description
RS-485 RX+, From M&C to CSAT A&B
RS-485 RX-, From M&C to CSAT A&B
RS-485 TX+, To M&C from CSAT A&B
RS-485 TX-, To M&C from CSAT A&B
Shorted to pin K = CSAT B Online
Shorted to pin K = CSAT A Faulted
Shorted to pin K = CSAT B Faulted
Ground = Manual, Open = Auto
Shorted to pin K = CSAT A Online
Momentary short to GND, otherwise OPEN
J8
4-17
Revision 1
MN/CSAT506025.IOM

Advertisement

Table of Contents
loading

Table of Contents