12.5.1 INSTALLATION OF THE SWITCHBOX

WARNING
Danger from electric current!
Risk of injury and damage to the device.
Before starting with the installation of the switchbox, the manual system must be
switched off and the mains plug disconnected.
3
2
P_01159
4
Connection for
Corona guns
Connection for
Tribo guns
ORDER NUMBER DOC 2354920
P_01183
A
B
C
1
Procedure:
1. Screw switchbox (1) to adapter plate (3) with
screws (2).
2. Use screws (4) to screw adapter plate with fi tted
switchbox onto the back side of trolley's front
plate.
3.
Pull the spray gun cable out of the socket (A) on
the control unit.
4.
Plug the switchbox's electrical cable (B) into the
socket (A) on the control unit and secure it with
the protective sleeve.
5.
Connect the spray gun to the appropriate
connection on the switchbox and secure it with
the protective sleeve of the spray gun cable.
6.
Set the switch (C) on the switchbox to the
desired spray gun type.