Set Time (hh:mm:ss) – Use the HH:MM:SS time format to set the time, where HH=hour [00-
23]; MM=minutes [00-59]; and SS=seconds [00-59]).
•
Set Date (dd/mm/yy) – Use the DD/MM/YY European time format to set the date, where
DD=day [01-31]; MM=month [01-12]; and YY=year [00-99].
Click [Submit] to save.
•
Adjustment for Internal 10 MHz Reference – Enter a value from -999 to +999 to set the
adjustment for the Internal 10 MHz High Stability Reference.
Click [Submit] to save.
Save/Load Configuration
This section allows you to save, and then load (recall) up to 10 configuration sets:
•
To save a configuration set:
o First, adjust all operational configuration parameters to suit.
o Then, use the top (Save) Select Location dropdown to select 1 through 10.
o Finally, click [Save Configuration] to store the configuration set.
•
To load (recall) a configuration set:
o First, use the bottom (Load) Select Location dropdown to select 1 through 10.
o Then, click [Load Configuration] to recall the selected configuration set.
Redundancy
This section is reserved for future use.
BERT
(Where BERT is the acronym for Bit Error Rate Test)
•
Tuner Select – Use the drop-down list select the active tuner (demodulator). Depending on
the chassis configuration, the minimum selection is 1 or 2; the maximum is from 1 to 12.
Click [Submit Changes] when done. Any further BERT configuration or operational settings
will apply to the selected tuner.
BERT Config
•
Configure the Rx BERT State as On or Off.