SRAM RockShox RS-1 Service Manual page 31

Table of Contents

Advertisement

Fully extend the rebound damper shaft. Push the syringe handle down, then
13
release the plunger. Allow the bladder to come to a natural resting position
by waiting a few moments until the syringe stops filling.
Use a rag to cover the bleed tip and Charger bleed port, then unthread and
remove the syringe.
⚠ CAU T ION - E YE H AZA RD
Fluid may eject from the bladder assembly if the bladder is not in its resting
position. Wear safety glasses.
Install the bleed screw.
14
Cycle the rebound damper shaft a few times.
Remove the bottom bolt from rebound damper shaft.
Clean the Charger 2 Damper™ assembly.
15
T10
1.1-2.3 N·m (10-20 in-lb)
Bleed Procedure
31