PROFIBUS Interface
Command Table: Save to Flash (Command ID 75h):
Word
DO
1.
Parameter Channel Control
2.
-
3.
-
4.
-
For this command, the MC software must be stopped (with command "35h: Stop MC and
Application Software").
The PROFIBUS Interface will stay active while the MC software is stopped.
Command Table: Delete All Entries (RAM) (Command ID 81h)
Word
DO
1.
Parameter Channel Control
2.
-
3.
-
4.
-
Command Table: Delete Entry (Command ID 82h):
Word
DO
1.
Parameter Channel Control
2.
Entry Number
3.
-
4.
-
Command Table: Write Entry (Command ID 83h)
Word
DO
1.
Parameter Channel Control
2.
Entry Number
3.
Block Size (even number of bytes)
4.
-
Command Table: Write Entry Data (Command ID 84h)
Word
DO
1.
Parameter Channel Control
2.
Entry Number
3.
Data
4.
Data
Command Table: Get Entry (Command ID 85h)
Word
DO
1.
Parameter Channel Control
2.
Entry Number
3.
-
4.
-
NTI AG / LinMot
User Manual PROFIBUS Interface / 15/05/2012
LinMot
DI
Parameter Channel Status
-
-
-
DI
Parameter Channel Status
-
-
-
DI
Parameter Channel Status
Entry Number
-
-
DI
Parameter Channel Status
Entry Number
Block Size
-
DI
Parameter Channel Status
Entry Number
Data
Data
DI
Parameter Channel Status
Entry Number
Block Size
-
®
Page 15/25