Fuser Ac Power Control - Xerox Phaser 3450 Service Manual

Hide thumbs Also See for Phaser 3450:
Table of Contents

Advertisement

>>Feature
• Insulating resistance : over 50MΩ(at DC 500V)
• Insulating revisiting pressure Must be no problem within 1min. (at 1500Vzc, 10mA)
• Leaking voltage : under 3.5mA
• Running voltage : under 50A peak (at 25°C, Cold start)
Under 60A peak (in other conditions)
• Rising Time : Within 2sec
• Falling Time : over 20ms
• Surge : Ring Wave 6KV-500A (Normal, Common)
>>Environment Condition
• Operating temperature range : 0°C~50°C
• Maintaining temperature range : -25°C~85°C
• Maintaining humid range : 10% ~90% RH
• Operating atmospheric pressure range : 1
>>EMI Requirement
CISPR ,FCC, CE, MIC, C-Tick,
>>Safty Requrement
IEC950 UL1950, CSA950, C-UL, NOM, TUV, Semko, Nemko, iK, CB, CCC(CCIB),GOST, EPA

4.3.3 Fuser AC Power Control

Fuser (HEAT LAMP) gets heat by using AC power. The AC power controls the switch with the Triac, a semiconductor
switch. The 'On/Off control' is operated when the gate of the Triac is turned on/off by Photo triac, which is insulting part.
In the other words, the AC control part is passive circuit, so it turns the heater on/off with taking signal from engine control
part. When the 'HEATER ON' signal is turned on at engine, the LED of PC1 (Photo Triac) takes the voltage and flashes.
From the flashing light, the Triac part (light receiving part) takes the voltage, and the voltage is supplied to the gate of Triac
and flows into the Triac. As a result, the AC current flows in the heat lamp, and heat is occurred.
On the other hand, when the signal is off, the PC1 is off, the voltage is cut off at the gate of Triac, the Triac becomes off,
and then the heat lamp is turned off.
>>Triac (THY1) feature :12A,600V SWITCHING
>>Phototriac Coupler (PC3)
• Turn On If Current : 16mA
• High Repetive Peak Off State Voltage : Min 600V
Summary of product
Service Manual
4-13