Battery Status
PWR Limit: The inverter maximum output power set by one of the power limiting options:
l
RRCR
o
Smart energy manager (Feed-in limitation)
o
P(f)
o
Q(U)
o
Cos Phi: The ratio between active to reactive power
l
Power Prod: The power produced by the inverter
l
For more information, refer to the following application notes:
Power Control Application Note, available on the SolarEdge website at
o
http://www.solaredge.us/files/pdfs/application_note_power_control_configuration.pdf
Feed-in Limitation Application Note, available on the SolarEdge website at
o
http://www.solaredge.us/files/pdfs/products/feed-in_limitation_application_note.pdf
Battery Status
This screen is displayed only when the battery is configured, and shows the battery identification
information, its charging status and power, and the operating mode.
B S N :
X X X X X X X X X
S O E : 8 9 %
T o t a l :
S t a t e :
BSN: Battery serial number
l
ID: Battery identification - should be 24 as set up above
l
SOE: State of Energy - the battery capacity percentage (calculated as Available Energy\Max. Energy)
l
PWR: The charging or discharging power (in Watts) according to the battery state (see below)
l
Total: The total discharged energy in Watt/hour
l
State: The battery status: Charging/ Discharging, Idle, Init (pre-heating) or Fault <error code>.
l
Time Of Use Status
This screen is sisplayed only if TOU is configured, and shows information about the TOU settings for the
site.
N a m e :
x x x x
L a s t
S y n c :
S o u r c e :
S e t
U n t i l :
Name: The TOU profile file name
l
Last Sync: Date when the time-of-use profile was loaded from the monitoring portal
l
Source: the source from which the TOU profile was uploade:
l
Remote - Profile uploaded from the SolarEdge monitoring portal
o
Local - Profile uploaded from an SD card
o
Set Until: The date until the current profileis applicable
l
54
I D : 2 4
W W W W W
P W R :
0 W
0 W h
I d l e
< D a t e >
< R e m o t e >
< d a t e >
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0