Appendix C: Replacing and Adding System
Components
NOTE
If you are permanently disassembling the installation or part of it, make sure to use the disposal 
methods dictated by local regulations.

Fuse Replacement

The inverter is equipped with a fuse, located at the top right corner of the inverter.
Fuse replacement kits are available from SolarEdge or you can use other fuses with identical ratings.
 1.  Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC voltage is safe 
(<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five 
minutes for the input capacitors of the inverter to discharge.
AVERTISSEMENT!
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement est indiqué sur l'écran
LCD, attendez cinq minutes pour que les condensateurs d'entrée de l'onduleur soient déchargés.
 2.  Turn OFF the DC Safety Unit . 
 3.  Open and remove the inverter cover.
 4.  Remove the existing fuse from the upper corner of the inverter and replace with a new fuse.
 5.  Close the inverter cover.
 6.  Turn ON:
 
The   i nverter ON/OFF switch
l
 
The DC Safety Unit 
l
 7.  Verify proper system operation. 
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1

Appendix C: Replacing and Adding System Components

Figure 35: Inverter fuse