SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
Overload Sensor Check (Toucan 800 & Toucan 800 DI)
Machine manufactured before 2010
Check the overload sensor, located on the platform
support, to ensure proper operation. Wedge a block (P/N :
ST2741) as illustrated above to activate the overload
sensor and keep it activated. The system is functioning
properly if :
1. From the Platform Control Console :
• An acoustic alarm sounds.
• The overload red light indicator flashes on the
platform control panel.
• Each attempt to perform a movement actuates
the orange light indicator on the platform control
panel.
• Every function is disabled from the upper control
panel.
2. From the Ground Control Console :
• An acoustic alarm sounds.
• The overload red indicators on the platform
control panel and on the ground control console
flash.
• Every function is disabled from the ground
control console.
31210031
Machine manufactured after 2010
– JLG Lift –
2-7