Soft Touch System Light And Alarm (Option)4-5; Shut Down And Park - JLG Toucan 800 Operation And Safety Manual

Table of Contents

Advertisement

1. Raise the mast or the jib (generally the reverse
movements to the one that caused the alarm to
sound).
2. Identify the cause.
3. Perform the movement which will clear the
machine and prevent contact with the obstacle.
If the examination of the surroundings does not reveal
any possible obstacle, the alarm may have been
triggered by the telescopic mast jamming which could
be due to :
• A foreign body entering the guiding system.
• A lack of lubrication.
• Incorrect operation.
NOTE: The slack chain and light alarms are also
operational from the ground control station.
IF THE SLACK CHAIN ALARM HAS BEEN TRIGGERED BY MAST
JAMMING, DISCONTINUE OPERATION IMMEDIATELY. DO NOT
USE
THE
MANUAL
LOWERING
OCCUPANTS MUST BE RESCUED AND THE MACHINE SERVICED
BY A QUALIFIED TECHNICIAN.
Soft Touch System Light and Alarm (Option)
The soft touch system detects contacts with outside
obstacles under the platform.
When this system is actuated, all the movements of the
platform are disabled, an acoustic alarm sounds and
the movement cut off indicator (orange) lights up on
the platform control panel.
Procedure to follow in case this feature is actuated :
1. Return all controls to neutral.
2. Locate the part of the platform contacting or
interfering with the outside obstacle.
3. Determine the appropriate clearance movement
(generally the opposite movement to the one that
caused the contact).
4. Actuate and keep actuated the auxiliary power
button (
) BEFORE operating the functions
required to clear the obstacle.
This feature is operational only when the platform is
controlled from the platform control panel.
31210031
CONTROLS.
PLATFORM
– JLG Lift –
SECTION 4 - MACHINE OPERATION
4.5

SHUT DOWN AND PARK

To shut down and park the machine, the procedures
are as follow :
1. Drive machine to a reasonably well protected
area.
2. Ensure mast is lowered and jib stowed.
3. Push in the Emergency Stop at Platform Control
Station.
4. Push in the Emergency Stop at Ground Control
Station. Position Platform/Off/Ground select
switch to center OFF.
5. Toucan 800 : Position the circuit-breaker to its "O"
position.
Toucan 870 : Depress the circuit breaker push
button.
6. If necessary, cover Platform Controls to protect
instruction placards, warning decals and
operating controls from hostile environment.
7. Charge the batteries if the LEDs on the discharge
indicator are orange or red.
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toucan 870

Table of Contents