SECTION 1 - SAFETY PRECAUTIONS
neutral and stop before moving the switch to the
next function. Operate controls with slow and even
pressure.
• Park the machine in stowed position when not in
service.
• Do not allow personnel to tamper with or operate
the machine from the ground with personnel in the
platform, except in an emergency.
• Do not carry materials directly on platform railing
unless approved by JLG.
• When two persons are in the platform, the operator
shall be responsible for all machine operations.
• Always ensure that power tools are properly stowed
and never left hanging by their cord from the
platform work area.
• Supplies or tools which extend outside the platform
are prohibited unless approved by JLG.
• When driving, always position extending structure
over rear axle in line with the direction of travel.
Remember, if extending structure is over the front
axle, steer and drive functions will be reversed.
• Do not assist a stuck or disabled machine by
pushing, pulling, or by using extending structure
functions. Only pull the unit from the towing points
on the chassis.
• Do not place extending structure or platform against
any structure to steady the platform or to support
the structure.
• Stow extending structure and shut off all power
before leaving machine.

Trip and Fall Hazards

JLG recommends that occupants of the platform wear
a full body harness with a lanyard attached to an
authorized lanyard anchorage point. For further
information regarding fall protection requirements on
JLG products, contact JLG Industries, Inc.
• Before operating the machine, make sure all gates
are closed and fastened in their proper position.
1-2
• Keep both feet firmly positioned on the platform
floor at all times. Never use ladders, boxes, steps,
planks, or similar items on platform to provide
additional reach.
• Always enter or leave the platform using the access
gate.
• Use extreme caution when entering or leaving
platform. Be sure that the mast assembly is fully
lowered. Face the machine, maintain "three point
contact" with the machine, using two hands and one
foot or two feet and one hand during entry and exit.

Electrocution Hazards

• This machine is not insulated and does not provide
protection from contact or proximity to electrical
current.
• Maintain distance from electrical lines, apparatus, or
any
energized
according to the Minimum Approach Distance
(MAD) as shown in Table 1-1.
• Allow for machine movement and electrical line
swaying.
Table 1-1. Minimum Approach Distances (M.A.D.)
Voltage Range
(Phase to Phase)
0 to 50 kV
Over 50 kV to 200 kV
Over 200 kV to 350 kV
Over 350 kV to 500 kV
Over 500 kV to 750 kV
Over 750 kV to 1000 kV
NOTE: This requirement shall apply except where
employer, local or governmental regulations
are more stringent.
– JLG Lift –
(exposed
or
insulated)
MINIMUM APPROACH DISTANCE
in Meters
3
5
6
8
11
14
31210031