EMB-MP HAWKER Charger (40 or 70 A)

a. Charge indicator (green)
b. Final charge indicator (yellow)
c. Battery indicator charge completed (green)
d. Fault indicator (red)
e. Circuit breaker
Charging the battery :
- Plug the charger into the mains (single phase 2 poles +
ground).
- Once the charger is connected, all the leds begin to flash
for a short period of time, indicating the charger is com-
pleting a self-test.
- The leds (c) and (d) will then flash for a short period of
time, indicating the charger is in "automatic starting"
mode.
- The charging phase starts, the green led (a) flashes
slowly (Frequency = 1 second) during the duration of
the charge.
- Once the final charging phase has been reached
(approximately 80%), led (a) still flashes and led (b)
lights up fixed.
- At the end of the charging process, both leds (a) and (c)
are on fixed.
Equalization charge :
- When the charger is doing an equalization charge :
• both leds (a) and (c) flash slowly.
• Led (b) is lit fixed.
Fault indicator :
- Should the transformer overheat, the red led (d) flashes
quickly (Frequency = 0,2 second).
- If the battery does not reach 2.4 V/cell after a 10 hour
charge, the charging process stops and the red led (d)
lights up.
It is advisable to have either the charger or the battery
checked by a technician.
31210031
SECTION 4 - MACHINE OPERATION
Leds signal :
OFF = the led is off
ON = the led is lit fixed
BL = the led flashes (T=1 second)
BV = the led flashes quickly (T = 0.2 second)
*
= the led can be on or off, depending on the state of
charge of the battery and on the charger's opera-
tion at that moment.