Directed 5906 Installation Manual page 17

Responder hd, lcd, led and 1-way models security and remote start
Table of Contents

Advertisement

3. Confirmation Chirps
1. On w/Warn Chirps ON: arm, disarm, and sensor Warn Away chirps are active.
2. On w/Warn Chirps OFF: arm and disarm chirps are active, Warn Away chirps are defeated.
3. OFF w/Warn Chirps ON: arm and disarm chirps are defeated, Warn Away chirps are active.
4. OFF w/Warn Chirps OFF: arm, disarm, and sensor Warn Away chirps are defeated.
4. Siren Duration
1. 30sec: the siren output for full trigger activations and Panic Mode is 30 seconds.
2. 60sec: the siren output for full trigger activations and Panic Mode is 60 seconds.
5. Ign-controlled Locks
1. No Ign-locking: the door lock/unlock outputs will not activate when ignition is turned ON & OFF.
2. Lock & Unlock: the door lock & unlock output will activate when ignition is turned ON & OFF.
3. Lock Only: the door lock output will activate when ignition is turned ON.
4. Unlock Only: the door unlock output will activate when ignition is turned OFF.
6. Door Lock Pulses
1. Single: the door lock & unlock outputs will pulse once.
2. Double Unlock only: the unlock output only will pulse twice.
3. Double Lock only: the lock output only will pulse twice.
4. Double Lock & Unlock: the lock & unlock outputs will pulse twice.
7. Door Lock Output Duration
1. 0.8 sec.: the door lock output pulses will be 800 milliseconds in duration.
2. 3.5 sec.: the door lock pulses will be 3.5 seconds in duration.
3. 0.4 sec.: the door lock pulses will be 400 milliseconds in duration.
8. Ignition Controlled 2nd Unlock
1. Delayed: for Ign-controlled unlocking, the 2nd Unlock will activate 800 milliseconds after the first
(driver door) unlock.
2. Immediate: for Ign-controlled unlocking, the 2nd Unlock will activate at the same time as the first
(driver door) unlock.
9. Comfort Closure
1. No comfort Closure: Comfort Closure is defeated when arming
2. Comfort Closure 1: When arming the door lock pulse (or 2nd pulse for double pulses) will remain
ON for 20 seconds.
3. Comfort Closure 2: 800 milliseconds following the last door lock pulse (or 2nd pulse for double
pulses); the door lock output will turn ON again for 20 seconds.
10. Horn Function
1. Full Alarm Only: the horn output will pulse only during full trigger events.
2. Siren Function 20/30/40/50 milliseconds: The horn output will emulate the siren output with
selectable chirp output timing to compensate for OEM horn inefficiency.
11. Hood Switch Type
1. Normally Open: for vehicles with a hood switch that rests at power or ground when the hood is
OPEN.
2. Normally Closed: for vehicles with a hood switch that rests at power or ground when the hood is
CLOSED.
12. Sensor Full Trigger
1. Single: full trigger activation of only one sensor is required to fully trigger the alarm.
2. Double: full trigger activation of two sensors within a ten second period is required to fully trigger
the alarm.
17