en | Off-board points
With any failure to receive an expected response from the module, all keypads show a system
fault. The control panel sends a module trouble report to the central station (if configured for
module trouble reports).
13.2.3

Installation and control panel wiring (B299)

Calculate power consumption
Make sure that there is enough power for the module and the other powered devices that you
want to connect to the system.
Refer to On-board outputs, page 65.
Caution!
Remove all power (AC and battery) before making any connections. Failure to do so might
!
result in personal injury and/or equipment damage.
Notice!
Enclosure
Install the module in the enclosure with the control panel or in an adjacent enclosure that is
within the distances rated for the module: 200 ft (60 m) with 22 AWG (0.6 mm) wire or 500 ft
(152 m) with 18 AWG (1.0 mm) wire.
Installing the module
1.
2.
3.
Wiring to the control panel
Use either the terminal strip labeled with PWR, A, B, and COM on the module to wire to the
SDI2 terminals labeled on the control panel, or use the interconnect wiring connector and the
included interconnect cable.
For terminal wiring, use 18 AWG to 22 AWG (1.0 mm to 0.6 mm) wire.
Notice!
Use either the terminal strip wiring or interconnect wiring to the control panel. Do not use
both. When you connect multiple modules, you can combine terminal strip and interconnect
wiring connectors in parallel.
13.2.4

POPIT devices overview and wiring

Wire resistance on each sensor loop must be less than 100 Ω with the detection devices
connected. The terminal strip supports 12 to 22 AWG (2.0 to 0.6 mm) wires.
2018.07 | 10 | F.01U.303.996
Set the module address.
Hold the module mounting brackets onto the inside of the enclosure. Match the bracket
holes to a 3-hole mounting pattern on the enclosure
Use the supplied mounting screws to secure the module.
MOD-2
MODULE RELEASE
MOD-1
PWR+/R
PWR+/R
30
29
28
29
A/Y
A/Y
olice
olice
B/G
B/G
28
27
ting
ting
26
27
COM/B
COM/B
ire
ire
PWR+/R
PWR+/R
26
26
A/Y
A/Y
25
25
B/G
B/G
24
24
COM/B
COM/B
23
23
PWR A B COM
Installation Manual
Control Panels
MOD-2
MODULE RELEASE
MOD-1
PWR+/R
PWR+/R
30
29
28
29
A/Y
A/Y
olice
olice
B/G
B/G
27
28
ting
ting
COM/B
COM/B
26
27
ire
ire
PWR+/R
PWR+/R
26
26
A/Y
A/Y
25
25
B/G
B/G
24
24
COM/B
COM/B
23
23
Bosch Security Systems, Inc.
PWR A B COM