116 en | Approved applications
D1257RB/
______
D1257
D1260/D1260B
______
D8125
______
D8125MUX
______
D8128D
______
D8129
______
D9127T/U
______
D9210C
______
Ratings of other devices in the system that are not shown above:
____
______
____
______
____
______
____
______
1
The In Alarm calculation for the module is: 20 xQty + (16.25 x number of relays).
2
Currents listed are for the B450 only. Include plug-in device currents in calculations.
3
If using the proximity reader, add 100 mA to columns A, B, and C before calculating.
4
38 mA for each active relay.
5
Value=Minutes of alarm operation/60
6
Use 110 mA + reader. Do not exceed 260 mA.
Table 19.10: Current rating chart for standby battery calculations
General ampere-hour (Ah) calculation
In this calculation, use Total B and Total C from the above table, and standby time (in hours)
and alarm time (in minutes) from the table below.
(Total B x standby time (in hours)) + (Total C x (alarm time (in minutes) / 60)) x1.15 =Total Ah
of battery
Total Ah requirements must not exceed the Ah capacity of batteries:
Application
Residential Burglary
Proprietary Burglary
Central Station (Bank)
Central Station (Mercantile)
2018.07 | 10 | F.01U.303.996
104
xQty
=______
140
xQty
=______
60
xQty
=______
140
xQty
=______
25
xQty
=______
20
xQty
=______
0.8
xQty
=______
110
xQty
=______
_____
xQty
=______
_____
xQty
=______
_____
xQty
=______
_____
xQty
=______
Total A=______
One D126 Battery=7 Ah
Two D126 Batteries=14 Ah
One D1218 Battery=17.2 or 18 Ah
Two D1218 Batteries=34.4 or 36 Ah
10+
xQty
140
xQty
60
xQty
140
xQty
25
xQty
20
xQty
0.8
xQty
100
xQty
______
xQty
______
xQty
______
xQty
______
xQty
Total B=______
Standby time (in hours)
minimum
4
4
72
4
Installation Manual
=______
225
xQty
=______
250
xQty
=______
60
xQty
=______
140
xQty
=______
50
xQty
=______
Refer to
footnote
1
=______
0.8
xQty
=______
110
6
xQty
=______
____
xQty
=______
____
xQty
=______
____
xQty
=______
____
xQty
Total C=______
Alarm time (in minutes)
minimum
4
N/A
N/A
N/A
Bosch Security Systems, Inc.
Control Panels
=______
=______
=______
=______
=______
=______
=______
=______
=______
=______
=______
=______