Parameter Mapping Lists
VLT 5000 series
Parameter
611 Data log: Motor frequency
Table 5.234 Conversion of Parameter 611
VLT 5000 series
Parameter
612 Data log: Motor voltage
Table 5.235 Conversion of Parameter 612
VLT 5000 series
Parameter
613 Data log: Motor current
5
5
Table 5.236 Conversion of Parameter 613
VLT 5000 series
Parameter
614 Data log: DC link voltage
Table 5.237 Conversion of Parameter 614
VLT 5000 series
Parameter 615 Fault log: Error
code
Table 5.238 Conversion of Parameter 615
VLT 5000 series
Parameter
616 Fault log: Time
Table 5.239 Conversion of Parameter 616
VLT 5000 series
Parameter
617 Fault log: Value
Table 5.240 Conversion of Parameter 617
VLT 5000 series
Parameter 618 Reset of kWh counter 15-06 Reset kWh Counter
Options
[0] No reset
[1] Reset
Table 5.241 Conversion of Parameter 618
VLT 5000 series
Parameter 619 Reset of Hours
run
Options
[0] No reset
[1] Reset
Table 5.242 Conversion of Parameter 619
38
Operating Instructions
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
15-30 Alarm Log: Error
Code
FC 302 series
15-32 Alarm Log: Time
FC 302 series
15-31 Alarm Log: Value
FC 302 series
[0] Do not reset
[1] Reset counter
FC 302 series
15-07 Reset Running Hours
Counter
[0] Do not reset
[1] Reset counter
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
VLT 5000 series
Parameter 620 Operation mode
Options
[0] Normal operation
[1] Function with deactivated
inverter
[2] Control card test
[3] Initialisation
Table 5.243 Conversion of Parameter 620
VLT 5000 series
Parameter
621 Name plate: VLT
Table 5.244 Conversion of Parameter 621
VLT 5000 series
Parameter
622 Name plate: Power section
Table 5.245 Conversion of Parameter 622
VLT 5000 series
Parameter 623 Name plate: VLT
®
Table 5.246 Conversion of Parameter 623
VLT 5000 series
Parameter 624 Name plate: Software version no. Not converted
Table 5.247 Conversion of Parameter 624
VLT 5000 series
Parameter
625 Name plate: LCP ID no.
Table 5.248 Conversion of Parameter 625
VLT 5000 series
Parameter
626 Name plate: Data base ID
Table 5.249 Conversion of Parameter 626
VLT 5000 series
Parameter
627 Name plate: Power ID no.
Table 5.250 Conversion of Parameter 627
VLT 5000 series
Parameter 628 Name plate: Application type
Table 5.251 Conversion of Parameter 628
VLT 5000 series
Parameter 629 Name plate: Application type no. Not converted
Table 5.252 Conversion of Parameter 629
FC 302 series
14-22 Operation Mode
[0] Normal operation
Not supported
[2] Control card test
[3] Initialisation
FC 302 series
®
Not converted
type
FC 302 series
Not converted
FC 302 series
Not converted
ordering no.
FC 302 series
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
MG37E102