Parameter Mapping Lists
VLT 5000 series
Parameter 707 PID Velocity Feed-
forward
Options
0 – 65000
Table 5.262 Conversion of Parameter 707
VLT 5000 series
Parameter 708 PID Acceleration
Feed-forward
Options
0 – 65000
5
5
Table 5.263 Conversion of Parameter 708
VLT 5000 series
Parameter 709 PID Velocity filter
Options
-500000 – 500000
Table 5.264 Conversion of Parameter 709
Parameter
Options
Table 5.265 Conversion of Parameters 710 to 779
VLT 5000 series
Parameter
780 Dead time compensation
Options
[0] Off
[1] On
Table 5.266 Conversion of Parameter 780
Parameter
Options
Table 5.267 Conversion of Parameter 781
VLT 5000 series
Parameter 795 - 799 User defined
(read only)
Options
User defined
Table 5.268 Conversion of Parameters 795 to 799
40
Operating Instructions
FC 302 series
32-65 Velocity Feed-
Forward
0 – 100000
FC 302 series
32-66 Acceleration Feed-
Forward
0 – 100000
FC 302 series
33-26 Velocity Filter
-1073741824 – 107374203
VLT 5000 series
FC 302 series
710 - 779
19-10 -19-79
User defined
User defined
FC 302 series
Not supported
VLT 5000 series
FC 302 series
781 Program ID
Not supported
0 – 65000
FC 302 series
19-95 -19-99 User
defined (read only)
User defined
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
®
5.9 VLT
5000 Parameter Group 8
VLT 5000 series
Parameter
801 Baud rate selection
Table 5.269 Conversion of Parameter 801
VLT 5000 series
Parameter
802 Minimum station delay
Table 5.270 Conversion of Parameter 802
VLT 5000 series
Parameter 803 Time out after bus
error
Range
1 – 99
Table 5.271 Conversion of Parameter 803
VLT 5000 series
Parameter 804 Response after bus
time out
Range
[0] Off
[1] Freeze output
frequency
[2] Stop
[3] Jogging
[4] Max speed
[5] Stop and trip
[6] No com. option
control
[7] Select set up 4
Table 5.272 Conversion of Parameter 804
VLT 5000 series
Parameter 805 Function of control word
bit 10
Range
[0] No function
[1] Bit 10 = 1 => CTW active [1] Profile default
[2] Bit 10 = 0 => CTW active [2] CTW Valid, active
[3] Bit 10 = 1 => Time out
Table 5.273 Conversion of Parameter 805
FC 302 series
Not converted
FC 302 series
Not converted
FC 302 series
8-03 Control Timeout
Time
0.1 – 18000.0
FC 302 series
8-04 Control Timeout
Function
8-02 Control Word Source
[0] Off
[1] Freeze output
frequency
[2] Stop
[3] Jogging
[4] Max speed
[5] Stop and trip
Par. 802 to RS485
[10] Select set up 4
FC 302 series
8-14 Configurable
Control Word CTW
[0] None
low
[1] Profile default
MG37E102