Parameter Mapping Lists
Parameter
Data range
Table 5.167 Conversion of Parameter 440
Parameter
Data range
5
5
Table 5.168 Conversion of Parameter 441
Parameter
Data range
Table 5.169 Conversion of Parameter 442
Parameter
Data range
Table 5.170 Conversion of Parameter 443
Parameter
Table 5.171 Conversion of Parameter 444
Parameter
Options
Table 5.172 Conversion of Parameter 445
Parameter
Options
Table 5.173 Conversion of Parameter 446
Parameter
Table 5.174 Conversion of Parameter 447
34
Operating Instructions
VLT 5000 series
FC 302 series
440 Process PID
7-33 Process PID
proportional gain
proportional gain
0.00 – 10.00
0.00 – 10.00
VLT 5000 series
FC 302 series
441 Process PID
7-34 Process PID
integral time
integral time
0.01 – 9999.99
0.01 – 10000.00
VLT 5000 series
FC 302 series
442 Process PID
7-35 Process PID
differentiation time
Differentiation Time
0.00 – 10.00
0.00 – 10.00
VLT 5000 series
FC 302 series
443 Process PID diff.
7-36 Process PID
gain limit
Diff. Gain Limit
5.0 – 50.0
0.00 – 10.00
VLT 5000 series
FC 302 series
444 Process PID
Not supported
lowpass filter time
VLT 5000 series
FC 302 series
445 Flying start
1-73 Flying Start
[0] Off
[0] Disable
[1] On
[1] Enable
VLT 5000 series
FC 302 series
446 Switching
14-00 Switching
pattern
Pattern
[0] 60 AVM
[0] 60 AVM
[1] SFAVM
[1] SFAVM
VLT 5000 series
FC 302 series
447 Torque
Not supported
compensation
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
VLT 5000 series
Parameter
448 Gear ratio
Table 5.175 Conversion of Parameter 448
VLT 5000 series
Parameter
449 Friction loss
Table 5.176 Conversion of Parameter 449
VLT 5000 series
Parameter
450 Mains voltage
at mains fault
Range
180 – 690 V
Table 5.177 Conversion of Parameter 450
VLT 5000 series
Parameter
453 Gear ratio,
speed close loop
Range
0.01 – 100.00
Table 5.178 Conversion of Parameter 453
VLT 5000 series
Parameter
454 Dead time
compensation
Table 5.179 Conversion of Parameter 454
VLT 5000 series
Parameter
455 Frequency
range monitor
Table 5.180 Conversion of Parameter 455
VLT 5000 series
Parameter
457 Phase loss
functions
Options
[0] Trip
[1] Warning
Table 5.181 Conversion of Parameter 457
VLT 5000 series
Parameter
483 Dynamic DC
link compensation
Table 5.182 Conversion of Parameter 483
FC 302 series
Not supported
FC 302 series
Not supported
FC 302 series
14-11 Mains Voltage
at Mains Fault
100 – 800 V
FC 302 series
7-07 Speed PID
Feedback Gear Ratio
0.0001 – 32.0000
FC 302 series
Not supported
FC 302 series
Not supported
FC 302 series
14-12 Function at
Mains Imbalance
[0] Trip
[1] Warning
FC 302 series
Not supported