Danfoss MCA 194 Operating Instructions Manual page 29

Vlt devicenet converter vlt automationdrive fc 302 vlt 5000
Table of Contents

Advertisement

Parameter Mapping Lists
VLT 5000 series
Parameter 319 Terminal 42, Output Digital = Par. 5-32 DO
Parameter 321 Terminal 45, Output Digital = Par. 5-33 DO
Options
[28] Brake, no brake
warning
[29] Brake ready, no
fault
[30] Brake fault
[31] Relay 123
[32] Mechanical brake
control
[34] Extended
mechanical brake
control
[35] Safety Interlock
[36] 0 – 100 Hz ⇒ 0 – 20
mA
[37] 0 – 100 Hz ⇒ 4 – 20
mA
[38] 0 – 100 Hz ⇒ 0 –
32000 p
[39] 0 – f max ⇒ 0 – 20
mA
[40] 0 – f max ⇒ 4 – 20
mA
[41] 0 – f max ⇒ 0 –
32000 p
[42] Ref min – Ref max
⇒ 0 – 20 mA
Table 5.108 Conversion of Parameters 319 to 321
MG37E102
Operating Instructions
FC 302 series
X30/7 (MCB 101)
Analogue values= Par. 6-50
AO 42
Pulse = Par. 5-66 DO X30/6
X30/7 (MCB 101)
Analogue values= Par. 6-60
AO X30/8
Pulse = Par. 5-66 DO X30/6
Par. 5-32 = [28] Brake, no
brake warning
Par. 5-32 = [29] Brake
ready, no fault
Par. 5-32 = [30] Brake fault
(IGBT)
Par. 5-32 = [31] Relay 123
Par. 5-32 = [32] Mech
brake ctrl
Par. 5-32 = [32] Mech
brake ctrl
Not supported
Not supported
Not supported
Not supported
Par. 6-50 = [109] Max Out
freq. 0 – 20 mA
Par. 6-50 = [130] Max Out
freq. 4 – 20 mA
Par. 5-66 = [109] Max Out
freq. 0 – 32000p Par. 568 =
32000
Par. 6-50 = [101] Reference
0 -20 mA
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
VLT 5000 series
Parameter 319 Terminal 42,
Output
Parameter 321 Terminal 45,
Output
Options
[43] Ref min – Ref max
⇒ 4 – 20 mA
[44] Ref min – Ref max
⇒ 0 - 32000 p
[45] FB min – FB max
⇒ 0 – 20 mA
[46] FB min – FB max
⇒ 4 – 20 mA
[47] FB min – FB max
⇒ 0 - 32000 p
[48] 0 – I max ⇒ 0 – 20
mA
[49] 0 – I max ⇒ 4 – 20
mA
[50] 0 – I max ⇒ 0 –
32000 p
[51] 0 – T lim ⇒ 0 – 20
mA
[52] 0 – T lim ⇒ 4 – 20
mA
[53] 0 – T lim ⇒ 0 –
32000 p
[54] 0 – T nom ⇒ 0 –
20 mA
[55] 0 – T nom ⇒ 4 –
20 mA
[56] 0 – T nom ⇒ 0 –
32000 p
[57] 0 – P nom ⇒ 0 –
20 mA
[58] 0 – P nom ⇒ 4 –
20 mA
[59] 0 – P nom ⇒ 0 –
32000 p
Table 5.109 Conversion of Parameters 319 to 321
FC 302 series
Digital = Par. 5-32 DO X30/7
(MCB 101)
Analogue values= Par. 6-50
AO 42
Pulse = Par. 5-66 DO X30/6
Digital = Par. 5-33 DO X30/7
(MCB 101)
Analogue values= Par. 6-60
AO X30/8
Pulse = Par. 5-66 DO X30/6
Par. 6-50 = [131] Reference 4
-20 mA
Par. 5-66 = [101] Reference 0
– 32000p Par. 5-68 = 32000
Par. 6-50 = [102] Feedback 0
-20 mA
Par. 6-50 = [132] Feedback 4
-20 mA
Par. 5-66 = [102] Feedback 0
– 32000p Par. 5-68 = 32000
Par. 6-50 = [103] Motor
current 0 -20 mA
Par. 6-50 = [133] Motor
current 4 -20 mA
Par. 5-66 = [103] Motor
current 0 - 32000p Par. 5-68
= 32000
Par. 6-50 = [104] Torque
related to limit 0 - 20 mA
Par. 6-50 = [134] Torque
related to limit 4 - 20 mA
Par. 5-66 = [104] Torque
related to limit 0 – 32000p
Par. 5-68 = 32000
Par. 6-50 = [105] Torque
related to norm 0 - 20 mA
Par. 6-50 = [135] Torque
related to norm 4 - 20 mA
Par. 5-66 = [105] Torque
related to norm 0 – 32000p
Par. 5-68 = 32000
Par. 6-50 = [106] Power
related to norm 0 - 20 mA
Par. 6-50 = [136] Power
related to norm 4 - 20 mA
Par. 5-66 = [106] Power
related to norm 0 – 32000p
Par. 5-68 = 32000
27
5
5

Advertisement

Table of Contents
loading

Table of Contents