Parameter Mapping Lists
®
5.6 VLT
5000 Parameter Group 5
VLT 5000 series
Parameter
500 Address
Range
0-126
Table 5.183 Conversion of Parameter 500
VLT 5000 series
Parameter
501 Baud rate
Options
[0] 300
[1] 600
[2] 1200
[3] 2400
[4] 4800
[5] 9600
Table 5.184 Conversion of Parameter 501
VLT 5000 series
Parameter
502 Coasting
Parameter
503 Quick - Stop
Parameter
504 DC brake
Parameter
505 Start
Parameter
506 Reversing
Parameter
507 Setup select
Parameter
508 Preset reference
select
Parameter
Unsigned 8 (5)
type
Options
[0] Digital input
[1] Bus
[2] Logic AND
[3] Logic OR
Table 5.185 Conversion of Parameter 502-508
VLT 5000 series
Parameter
509 Bus Jog 1
Range
0.0 – par. 202
Table 5.186 Conversion of Parameter 509
VLT 5000 series
Parameter
510 Bus Jog 2
Range
0.0 – par. 202
Table 5.187 Conversion of Parameter 510
VLT 5000 series
Parameter
512 Telegram Profile
Range
[0] Fieldbus profile
[1] FC profile
Table 5.188 Conversion of Parameter 512
MG37E102
Operating Instructions
FC 302 series
8-31 Address
0-126
FC 302 series
8-32 Baud Rate
Not supported
Not supported
Not supported
[0] 2400
[1] 4800
[2] 9600
FC 302 series
8-50 Coasting Select
8-51 Quick Stop Select
8-52 DC Brake Select
8-53 Start Select
8-54 Reversing Select
8-55 Set-up Select
8-56 Preset Reference
Select
Unsigned 8 (5)
[0] Digital input
[1] Bus
[2] Logic AND
[3] Logic OR
FC 302 series
8-90 Bus Jog 1 Speed
0.0 – par. 4-13
FC 302 series
8-91 Bus Jog 2 Speed
0.0 – par. 4-13
FC 302 series
8-10 Control Profile
[1] ProfiDrive profile
[0] FC profile
Danfoss A/S © Rev. 2014-03-06 All rights reserved.
VLT 5000 series
Parameter
513 Bus time interval
Table 5.189 Conversion of Parameter 513
VLT 5000 series
Parameter
514 Bus time interval function
Table 5.190 Conversion of Parameter 514
VLT 5000 series
Parameter
515 Reference %
Table 5.191 Conversion of Parameter 515
VLT 5000 series
Parameter
516 Reference Unit
Table 5.192 Conversion of Parameter 516
VLT 5000 series
Parameter
517 Feedback
Table 5.193 Conversion of Parameter 517
VLT 5000 series
Parameter
518 Frequency
Table 5.194 Conversion of Parameter 518
VLT 5000 series
Parameter
519 Frequency x scaling
Table 5.195 Conversion of Parameter 519
VLT 5000 series
Parameter
520 Current
Table 5.196 Conversion of Parameter 520
VLT 5000 series
FC 302 series
Parameter 521 Torque
16-22 Torque [%]
16-21 Torque [%] high resolution
Table 5.197 Conversion of Parameter 521
VLT 5000 series
Parameter
522 Power, kW
Table 5.198 Conversion of Parameter 522
VLT 5000 series
Parameter
523 Power, HP
Table 5.199 Conversion of Parameter 523
FC 302 series
Not Converted
FC 302 series
Not Converted
FC 302 series
16-02 Reference [%]
FC 302 series
16-01 Reference [Unit]
FC 302 series
16-52 Feedback[Unit]
FC 302 series
16-13 Frequency
FC 302 series
Not converted
FC 302 series
16-14 Motor current
FC 302 series
16-10 Input Power [kW]
FC 302 series
16-11 Input Power [hp]
35
5
5