Chapter 1: KC724 Board Features and Operation

Using External Power Sources

The maximum output current rating for each power regulator is listed in
design exceeds this value on any core power rail, power for that rail must be supplied
externally through the 12-position core power terminal block J6 (callout 7,
using a supply capable of providing the required current.
X-Ref Target - Figure 1-4
Caution!
Power) must be set to the OFF position before turning ON the main power switch (SW1) and applying
external power to the corresponding rail input pin on the core power terminal block J6 (callout 7,
Figure
Caution!
12
Send Feedback
Figure 1-4: Core Power Terminal Block
The SW10 power regulator enable switch (callout 8,
1-2).
The core power terminal block J6 has a maximum load current contact rating of 24A.
www.xilinx.com
J6
VCCINT_EXT
1
2
VCCBRAM_EXT
3
4
VCCAUX_EXT
5
6
VCCAUX_IO_EXT
7
8
VCCO_HP_EXT
9
10
VCCO_HR_EXT
11
12
GND