M a i n t e n a n c e S c r e e n
The Maintenance screen and maintenance screen options are used for diagnostic, troubleshoot-
ing, and maintenance operations.
Main screen displays the following:
•
Current Date and Time – The date and time are local to operator interface.
•
Sync # – Provides a means to silence and acknowledge all Red Lion display alarms from
any Red Lion display. Set the Sync # of each display to a unique number from 1-8. When
one is silenced, all others will be silenced.
•
HMI, Controller (Main PLC), and Remote Expansion I/O major and minor revisions – The
major and minor release of the programs are displayed. For the FLX system to function
properly the Major Revision of the HMI, Controller (Main PLC), and Remote Expansion
I/O must be the same. The minor revision means a change has been made in one program
but did not affect the functionality of the other program. The minor revisions for the pro-
grams do not have to match.
•
Maximum Pumps – The maximum number of pumps available based upon I/O configura-
tion.
•
Maximum Devices – The maximum number of devices (loaders, multi-source loaders, gran-
ulators) available based upon I/O configuration.
•
Main PLC
o Maximum Pumps and Maximum devices based upon I/O configuration in Main
PLC.
o Expansion Inputs and Output Cards – The total number of input and output
expansion cards available for configuration.
•
Remote I/O (Only available when Remote I/O is configured)
o Maximum Pumps and Maximum devices based upon I/O configuration in Remote
I/O.
o Expansion Inputs and Output Cards – The total number of input and output
expansion cards available for configuration.
•
HMI IP address, Subnet Mask, Gateway address – The network address of the operator
interface.
•
HMI Network ID – The Operator Interface Ethernet port's MAC address as 17-character
text string.
M a i n t e n a n c e l
( c o n t i n u e d )
5 - 3