D e v i c e C o n f i g u r a t i o n S c r e e n
Each loader/receiver is configured individually. Proper login is required.
From the loader screen press the Setup button.
Depending upon I/O configurations, some loader configurations may not be available.
Fill Alarm
Activates a fill alarm if the demand is not satisfied or hopper does not fill before the load
time is reached. This option requires an option fill sensor in the receiver. This is a passive
alarm; the pump will continue to service the loader.
Material Check
A material alarm is activated if the receiver or hopper is not filled by the loader within the
number of tries set by the user (setpoint). The Alarm can be configured as passive (the
pump will continue to service the loader) or active (the loader is automatically disabled and
requires an acknowledgement before enabling again).
Purge
Purge material from the conveying line at the end of the loading cycle. This function
requires the installation of a valve at the base of the drying hopper or vessel and I/O output
options required.
Discharge
Enable the discharge output during the discharge cycle. This function requires the installa-
tion of a positive discharge valve at the base of the drying hopper or vessel and I/O output
options are required.
Priority Load
The loader will be loaded before other loaders.
( c o n t i n u e d )